11.2.3.1

STO function test

An STO function test requires that both STO
checked for plausibility with the resulting STO status signals. In the event of a fault, the safety
function must be activated at both STO inputs. The drive controller must no longer be enabled.
STO
status
you are working with a fieldbus system, you can access detailed status information by transmitting
parameter E67 STO status, array E67[0] – E67[2]. They can be used as an alternative to STO
the plausibility check.
In applications with increased safety requirements such as SIL 3 or PL e, a safety controller must
check the connecting wiring. In applications with reduced safety requirements (i.e. up to SIL 2, PL d),
a standard controller can perform the STO function test. More information on the use of a standard
controller can be found in the IFA Report 2/2016 Sicherheitsbezogene Anwendungssoftware von
Maschinen – die Matrixmethode des IFA (Safety-related application software for machinery – The IFA
matrix method); see the chapter 9.5 Einsatz von Standardkomponenten für fehlerbeherrschende
Maßnahmen.
Manual PMC SR6 safety module
1005344-en-US-01
Intern
is made available directly on terminal X12 of the drive controller for monitoring purposes. If
Information
During the STO function test, the drive controller switches to the
operating state.
and STO
signals be switched in alternation and
a
b
for
status
switch-on lockout