Pilz PNOZ m ES EtherNet/IP Operating Manual

Pilz PNOZ m ES EtherNet/IP Operating Manual

Configurable, safe small controllers pnozmulti 2

Advertisement

PNOZ m ES EtherNet/IP
}
Configurable, safe small controllers PNOZmulti 2
Operating Manual-1003387-EN-05

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PNOZ m ES EtherNet/IP

  • Page 1 PNOZ m ES EtherNet/IP Configurable, safe small controllers PNOZmulti 2 Operating Manual-1003387-EN-05...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    General wiring guidelines Connecting the supply voltage Interface assignment Download modified project to the PNOZmulti system Set IP address Connection example Section 7 Operation Messages Web server 7.2.1 Password administration 7.2.2 Call web server Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 4 Contents Section 8 Technical Details Section 9 Order reference Product Accessories Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 5: Introduction

    Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ m ES EtherNet/IP. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 7: Overview

    128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus EtherNet/IP. Max. 1 PNOZ m ES EtherNet/IP can be connected to the base unit 2-port switch Device Level Ring (DLR) Integrated web server Please refer to the document "PNOZmulti System Expansion"...
  • Page 8: Front View

    0 V, 24 V: Supply connections IP address: for setting the IP address : Functional earth LED: – Power – – – L/A 1 – L/A 2 EtherNet/IP is registered trademark and patented technology, licensed by ODVA. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 9: Safety

    IEEE 802.3. The central controller (scanner) reads input information from the slaves and writes output information to the slaves as part of each cycle. As well as the cyclical transfer of usable data, the expansion module PNOZ m ES EtherNet/IP can also be used for dia- gnostic and commissioning functions.
  • Page 10: System Requirements

    Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 11: Function Description

    PNOZmulti Configurator. The base unit and the fieldbus mod- ule PNOZ m ES EtherNet/IP are connected via a jumper. After the supply voltage is switched on or the PNOZmulti control system is reset, the fieldbus module PNOZ m ES EtherNet/IP is configured and started automatically.
  • Page 12 Master for access to the payload data table (15 Bytes are returned to the Mas- ter). Detailed information on data exchange is available in the document "Communication Inter- faces PNOZmulti 2" in the section entitled "Fieldbus modules". Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 13: Block Diagram

    Function description Block diagram 24 V Module Ethernet/IP Supply Data (ST) Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 14: Installation

    Connect the base unit and the expansion module as described in the operating instructions for the base units. Connect the black/yellow terminator to the expansion module. Install the expansion module in the position in which it is configured in the PNOZmulti Configurator. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 15 Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 16: Commissioning

    Connect the supply voltage to the fieldbus module: 24 V terminal: + 24 VDC 0 V terminal: 0 V Protect the supply voltage as follows: – Circuit breaker, characteristic C - 6 A Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 17: Interface Assignment

    The following different options are available for setting the IP address. Set IP address via DIP switches IP address is set using the DIP switch on the front of the PNOZ m ES EtherNet/IP: The first three bytes of the IP address are: 192.168.1.
  • Page 18 If you are setting the IP address via the web server, the DIP switch must not be set to 255. If you are setting the IP address via the Ethernet/IP Scanner, the DIP switch must be set to 0 and DHCP must be active. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 19: Connection Example

    Commissioning Connection example Ethernet/IP Master Ethernet/IP Ethernet/IP Ethernet/IP Slave 1 Slave 2 Slave 3 Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 20: Operation

    The LEDs “POWER”, “DIAG”, “FAULT”, “IFAULT” and “OFAULT” will light up on the base unit. The fieldbus module PNOZ m ES EtherNet/IP is configured and started automatically. The LEDs "MS", "NS", "L/A1" and "L/A2" indicate the status of the PNOZ m ES EtherNet/IP on the EtherNet/IP. Messages...
  • Page 21: Web Server

    PNOZ m ES EtherNet/IP via the web server. In this case you will need to return the module to Pilz for it to be reset to its original delivery status. All the settings will be lost in the process.
  • Page 22: Call Web Server

    Operation 7.2.2 Call web server 1. Connect the PNOZ m ES EtherNet/IP to the PC. 2. Call up the HTML page: – http://192.168.1.xxx – For xxx, enter the value that you have set as the last byte of the IP address.
  • Page 23 EN 60068-2-1/-2 Temperature range -25 - 70 °C Climatic suitability In accordance with the standard EN 60068-2-30, EN 60068-2-78 Condensation during operation Not permitted Max. operating height above sea level 2000 m EN 61131-2 Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 24 0,5 Nm Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector 0,2 - 2,5 mm², 24 - 12 AWG Spring-loaded terminals: Terminal points per connec- tion Stripping length with spring-loaded terminals 9 mm Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 25 Technical Details Mechanical data Dimensions Height 101,4 mm Width 22,5 mm Depth 110,4 mm Weight 90 g Where standards are undated, the 2014-04 latest editions shall apply. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 26 Spring-loaded terminals, 10 pieces 783 543 PNOZ mmcxp 10 pcs. Screw terminals Screw terminals, 1 piece 793 542 PNOZ mmcxp 1 pc. Screw terminals Screw terminals, 10 pieces 793 543 PNOZ mmcxp 10 pcs. Operating Manual PNOZ m ES EtherNet/IP 1003387-EN-05...
  • Page 27 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...