[CYAN ERROR]
[GOBO ROTATION ERROR]
[STATIC
GOBO
WHEEL
ERROR]
[MOTOR PCB 3 ERROR]
[FROST ERROR]
[4F PRISM ERROR]
[8F PRISM ERROR]
[4F
PRISM
ROTATION
ERROR]
[8F
PRISM
ROTATION
ERROR]
[FOCUS ERROR]
[ZOOM ERROR]
[LAMP AIR IN (LOW) FAN
ERR.]
[LAMP AIR OUT (UP) FAN
ERR.]
[SHUTTER 1 ERROR]
[SHUTTER 2 ERROR]
[SPOT FILTER ERROR]
[FAN PCB ERROR]
[LAMP RIGHT FAN ERROR]
[LAMP LEFT FAN ERROR]
[LAMP
TEMPERATURE
ERROR]
[IGNITOR
TEMPERATURE
ERROR]
[LAMP
TEMP.
SENSOR
ERROR]
Failure detected during the reset of the Cyan flag, if
the Cyan flag of the CMY module is not located in its
default position
Failure detected during the reset of the rotation of the
rotating gobo, if the rotating gobos are not located in
the default positions
Failure detected during the reset of the static gobo
wheel, if this wheel is not located in the default position
Motor pcb 4U not detected
Failure detected during the reset of the effect FROST,
if this effect is not located in the default position.
Failure detected during the reset of the 4F effect prism,
if this effect is not located in the default position.
Failure detected during the reset of the 8F effect prism,
if this effect is not located in the default position.
Failure detected during the reset of the 4F effect prism
rotation, if this effect is not located in the default
position.
Failure detected during the reset of the 8F effect prism
rotation, if this effect is not located in the default
position.
Failure detected during the reset of the FOCUS, if the
focus lens is not located in its default position.
Failure detected during the reset of the ZOOM system,
if the focus lens is not located in its default position.
Air in blower for cooling the lamp failed, the lamp has
been switched OFF.
Air out blower for cooling the lamp failed, the lamp
has been switched OFF.
Failure detected during the reset
SHUTTER, if this effect is not located in the default
position.
Failure detected during the reset
SHUTTER, if this effect is not located in the default
position.
Failure detected during the reset of spot filter, if the
rotating gobos are not located in the default positions
Fan PCB not detected
Right blower for cooling the lamp failed, the lamp has
been switched OFF.
Left blower for cooling the lamp failed, the lamp has
been switched OFF.
This error message indicates that an overheating on
the lamp has occurred and the lamp has been switched
OFF by the product protection system.
This error message indicates that an overheating
on the ignitor has occurred and the lamp has been
switched OFF by the product protection system.
LAMP sensor damaged (open or in short circuit)
PROLIGHTS - Astra Hybrid420
Yellow
Yellow
Yellow
Purple
Purple
Purple
Purple
Purple
Purple
Purple
Purple
Purple
Purple
of the effect
Purple
of the effect
Purple
Purple
Acquamarine
Acquamarine
Acquamarine
Acquamarine
Acquamarine
Acquamarine
3U
3U
3U
4U
4U
4U
4U
4U
4U
4U
4U
4U
4U
4U
4U
4U
5U
5U
5U
5U
5U
5U
33

Advertisement

Table of Contents
loading

Table of Contents