Command Sds - Request Status After Executing Shading Correction Command; Command Sro - Sensor Read Out; Command Sgr, Sgg, Sgb, Sgir - Sensor Gain Set R, G, B And Nir; Command Tg - Trigger Origin - JAI LQ-201CL User Manual

Rgb color & nir 4cmos line scan camera
Table of Contents

Advertisement

Run Color shading correction (SDR=1)
7.32
Command SDS – Request Status After Executing Shading Correction
This command returns the status of the shading correction function, with the following parameters:
0=Not completed yet
1=Succeeded
2=Error1: Image too bright
3=Error2: Image too dark
4=Error3: Timeout occurred
7.33
Command SRO – Sensor Read Out
This command selects the readout format from the sensor.
Settings:
7.34
Command SGR, SGG, SGB, SGIR – Sensor Gain Set R, G, B and NIR
This command sets the reference gain for gain control.
Settings:
7.35
Command TG – Trigger Origin
Selects whether an external signal or an internal clock generator is used as a trigger
source.
Settings:
Associated commands:
7.36
Command TI – Trigger Input
Selects whether the External Trigger input signal is taken from the Camera Link connector, or from
the 12-pin connector. The 12-pin connector trigger input can be terminated by a 75 ohm terminator.
This is selected by a rear panel DIP-switch (SW1).
Settings:
7.37
Command TP – Trigger Polarity
LQ-201CL
Command
0= OFF (Full Frame)
1= Sub-sampling
2= Windowing
0= Low Gain
1= High Gain
Common for all channels
0=Internal clock generator
1=External signal
TI
TP
0=Camera Link connector
1=12-pin connector
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lq-201cl-f

Table of Contents