Pulse Width Control (Pwc) Mode - JAI LQ-201CL User Manual

Rgb color & nir 4cmos line scan camera
Table of Contents

Advertisement

6.3.6

Pulse Width Control (PWC) mode

In this mode, the exposure time and readout are activated by the external trigger pulse. The
exposure time depends on the pulse width provided.
To use this mode:
Set function
Trigger mode, PWC
Important Note:
 The minimum trigger interval
Scan mode
Full/Binning
Sub-sampling/windowing
 The available input trigger pulse width
Trigger input via
Camera link
12-pin
 One-push white balance by gain setting only.
 When the one-push white balance has been initiated and the rear panel LED shows orange, the
camera must receive continuous external trigger pulses corresponding to the frequency and duty
cycle used in the application.
TG
174clk
EEN
LVAL
DVAL
Data
LQ-201CL
TR=2
Trigger input via
Camera link
12-pin
Camera link
12-pin
available input trigger pulse width
2µs ~ 1s
50µs ~ 1s
154clk
611clk
Fig. 44 Pulse Width Control mode
38
Minimum interval (µs)
Exposure time + 30.8
Exposure time + 35.3
Exposure time + 18.9
Exposure time + 23.4
8clk
2048clk
AP0
8clk
AP2047