For the V and s curves there are the following relationships without overspeed distance:
Parameter
Acceleration method
t
Value from PSC1 response time data
Resp
+ delay in external shutdown chain
a
, a
n.a.
F
V
V
= V
+ a
a1
S
For the V and s curves with overspeed distance the following applies:
Parameter
Acceleration method
t
Value from PSC1 response time data
Resp
+ delay in external shutdown chain
a
, a
n.a.
F
V
V
= a
* t
a2
F
With its action the filter displaces upward the speed threshold set V
the application the new values for the response time (TResp = T
speed on shutdown by the PSC1 are to be taken into account.
PSC1-C-10 Installation manual V2.6
Version: 57E
* t
F
Resp
2
1/2
+ (V
+ 2 * a
* XF)
Resp
S
F
Remark
Delay in external shutdown chain from
relay / contactor, brake manufacturer
data etc.
Estimation from application
Remark
Delay in external shutdown chain from
relay / contactor, brake manufacturer
data etc.
Estimation from application
by an amount delta_v_filter. For
a
+ TFilter), as well as the resulting
PSC1