2.5.2 Mounting YQ to TC

(1) After confirming that there are no broken or bent YQ contact pins, fit the YQ in the TC and fasten it using the
supplied YQGUIDE (for the fastening method, see the next step, (2)). If repeatedly inserting and removing, be
sure to inspect the YQ pins before fitting. If pins are bent, correct them using something thin and flat such as
the edge of a knife.
(2) Fasten YQ to the TC on the target system using the supplied YQGUIDE. Fasten the screws equally in the four
corners using the supplied flat-blade screwdriver or a torque driver. The tightening torque of the YQGUIDE is
0.054 Nm (MAX.). Too great tightening causes bad connections.
However, four screws for fitting to the TC (M2 x 10 mm / 4 units) are included with the YQ.
R20UT0289JJ0100 Rev. 1.00
Sep 30, 2010
Target system
CHAPTER 2 SETUP PROCEDURE
EA
YQGUIDE supplied with YQ
YQ
TC
Page 18 of 28