Maintenance: Cooling system, general

Cooling system D34A MS KC

The engine cooling water is cooled by, e.g, a box cooler, a grid cooler, or any other external heat exchanger. The
same coolant (fresh water) is cooling the complete engine.
6.
7.
6.
1.
2.
Freshwater drain points (D)
D
D
Plus d'informations sur : www.dbmoteurs.fr
62
4.
3.
3.
5.
5.
D
1. Freshwater inlet
2. Freshwater pump
3. Engine
4. Lubrication oil cooler
5. Charge air cooler
6. Thermostat valve
7. Freshwater outlet