Maintenance Schedule - Volvo Penta D34A MS Operator's Manual

Non-classifiable control system
Table of Contents

Advertisement

Maintenance schedule

D34A MS
Daily before first start
General inspection engine and engine room
Check and make sure all valves are in the right position
Check lubrication oil level
Check marine gear oil level
Check coolant level
Drain water from fuel tank
Drain water from fuel pre-filter/water separator
Drain water from air vessel and air filter
Check engine control system (cables, etc.)
Check fuel control linkage
Check aftercooler drain pipe
Daily operation records
Inspection of valves and plugs
After start
Check lubrication oil filter differential pressure indicator
Check air-filter differential pressure indicator
Check if the instrumentation works properly
Check for leakages
Weekly
Check starting batteries; electrolyte level/load
Check electrical system for loose terminals/contacts
Check foundation bolts
Check lubrication oil for abnormal smell or water dilution
Check safety valves of air system
Check air system oiler
Check settings of valves and move valve to keep them operationable
Drain water from the fuel pre-filter/water separator
Drain crankcase ventilation water trap
Drain exhaust silencer (system) water trap
First 50-250 operating hours of new or recond. engines (First service)
Change lubrication oil
Change full flow and by-pass lubrication oil filters
Change governor lubrication oil filter
Check required lubrication oil change for marine gear
Check/adjust V-belts
Check/adjust valve clearance
Check/retighten bolts and nuts