Power supply/charger
Hide thumbs Also See for AL400ULPD8CB:

Advertisement

Quick Links

AL400ULX Series
Power Supply/Charger
Models Include:
AL400ULX
- Single Output.
AL400ULPD4
- Four (4) Fuse Protected Outputs.
AL400ULPD8
- Eight (8) Fuse Protected Outputs.
AL400ULXPD16
- Sixteen (16) Fuse Protected Outputs.
For a red enclosure add an "R" suffix to the part #, e.g. AL300ULPD8R
Installation Guide
Rev. 013019
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
AL400ULPD4CB
- Four (4) PTC Protected Outputs.
AL400ULPD8CB
- Eight (8) PTC Protected Outputs.
AL400ULXPD16
- Sixteen (16) PTC Protected Outputs.
More than just power.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL400ULPD8CB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altronix AL400ULPD8CB

  • Page 1 - Single Output. AL400ULPD4 AL400ULPD4CB - Four (4) Fuse Protected Outputs. - Four (4) PTC Protected Outputs. AL400ULPD8 AL400ULPD8CB - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs. AL400ULXPD16 AL400ULXPD16 - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
  • Page 2 Overview: Altronix AL400ULX is a power supply that converts a 115VAC, 60Hz input to a 12VDC or 24VDC regulating output (see specifications below). The AL400ULX is a base power supply unit for the UL Listed multi-output power supply/charger series: AL400ULPD4, AL400ULPD4CB, AL400ULPD8, AL400ULPD8CB, AL400ULXPD16, AL400ULXPD16CB (Refer to AL400ULX Series Power Supply Configuration Reference Chart below).
  • Page 3: Power Supply Output Specifications

    Specifications: Input: Battery Backup: • Input 115VAC, 60Hz, 3.5A. • Built-in charger for sealed lead acid or gel type batteries. Output: • Automatic switch over to stand-by battery when • Class 2 Rated power-limited output(s). AC fails. • 12VDC or 24VDC selectable output(s). •...
  • Page 4 Fig. 1 - AL400ULX Series CAUTION: De-energize unit prior to servicing. For continued protection against risk of electric shock and fire hazard replace fuse with the same type and rating. Do not expose to rain or moisture. Green Lead 115VAC power mains non power-limited Fig.
  • Page 5: Installation Instructions

    Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure.
  • Page 6: Led Diagnostics

    LED Diagnostics: Power Supply Board Red (DC) Green (AC) Power Supply Status Normal operating condition. Loss of AC. Stand-by battery supplying power. No DC output. Loss of AC. Discharged or no stand-by battery. No DC output. Red (Bat) Battery Status Normal operating condition.
  • Page 7: Power Distribution Module(S)

    Power Distribution Module(s): Fig. 2a - PD4UL Power Distribution Board Fig. 2b - PD4ULCB - Power Distribution Board Non Power-Limited Outputs Class 2 Power-Limited Outputs Replace fuses with the same type and rating 3.5A/250V DC Output to devices From Power Supply DC Output to devices From Power Supply 1P-4P Power Outputs,...
  • Page 8: Appendix A - Ul Listed Compatible Devices

    Appendix A - UL Listed Compatible Devices –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– A.1 Four (4) Wire Smoke Detectors Table A-1 below lists four (4) wire smoke detectors compatible with AL400ULX output. System Sensor Max Stand-by Alarm Current Detector Type Smoke Detector/Base Current (mA) (mA) B112LP Base 0.12...
  • Page 9 Notes: AL400ULX Series - 9 -...
  • Page 10 Notes: - 10 - AL400ULX Series...
  • Page 11 Enclosure Dimensions (BC300): AL400ULX, AL400ULXR, AL400ULPD4, AL400ULPD4CB, AL400ULPD8, AL400ULPD8CB 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm) 1.40” 1.40” 4.85” (123.2mm) 4.85” (123.2mm) (35.6mm) (35.6mm) 1.20” (30.5mm) 0.75” 0.75” 12.5” (317.5mm) 1.20” 1.20” (19.1mm) (19.1mm) (30.5mm) (30.5mm) 11.0” (279.4mm) 0.9375”...
  • Page 12 (38.1mm) (38.1mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. IIAL400ULX Series G06U MEMBER...

Table of Contents