Tab. 1/d
LOGIC "P"
AUTOMATED
OPEN A
SYSTEM STATUS
CLOSED
opens
WHEN OPENING
no effect
no effect
OPEN
(closing inhibited)
immediately
WHEN CLOSING
reverses to
opening
BLOCKED
opens
Tab. 1/e
LOGIC "PA"
AUTOMATED
OPEN A
SYSTEM STATUS
opens and closes
CLOSED
after the pause
WHEN OPENING
no effect
OPEN IN PAUSE
resets pause time
immediately
WHEN CLOSING
reverses to
opening
opens and closes
BLOCKED
after the pause
Tab. 1/f
LOGIC "Cn"
AUTOMATED
OPEN A
SYSTEM STATUS
CLOSED
opens
WHEN OPENING
no effect
no effect
OPEN
(closing inhibited)
immediately
WHEN CLOSING
reverses to
opening
BLOCKED
opens
 In brackets, the effects on the other inputs when the pulse is active
CLOSE
no effect
closes
immediately after
opening is
completed
closes
no effect
closes
CLOSE
no effect
time
closes
immediately
after opening is
completed
closes
no effect
closes
time
CLOSE
no effect
closes
immediately
after opening is
completed
closes
no effect
closes
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
no effect
no effect
(closing inhibited)
(closing inhibited)
blocks and when
blocks
disengaged
continues to
operation
close
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
resets pause
blocks
time
operation
(closing inhibited)
blocks and when
blocks
disengaged
continues to
operation
close
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
no effect
no effect
(closing inhibited)
(closing inhibited)
reverses to
blocks
opening and
closes after
operation
pause time
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
22
LOOP 1
LOOP 2
opens and once
opening is
no effect
completed closes if
disengaged
closes
immediately
no effect
after opening is
completed
closes when
prevents closing
disengaged
immediately
blocks and when
reverses to opening,
disengaged
and once opening is
continues to
completed closes if
close
disengaged
opens and once
opening is
no effect
completed closes if
(closing inhibited)
disengaged
LOOP 1
LOOP 2
opens and once
opening is
no effect
completed closes if
disengaged
closes
immediately
no effect
after opening is
completed
closes when
resets pause time
disengaged
immediately
blocks and when
reverses to opening,
disengaged
and once opening is
continues to
completed closes if if
close
disengaged
opens and once
opening is
no effect
completed closes if
(closing inhibited)
disengaged
LOOP 1
LOOP 2
opens
no effect
closes
immediately
no effect
after opening is
completed
closes when
no effect
disengaged
immediately
immediately
reverses to
reverses to
opening
opening
no effect
opens
(closing inhibited)