Advertisement

Installation Manual
820/860
Sliding Gate System
Leading the way ...
Leading the way ...
Leading the way ...

Advertisement

Table of Contents
loading

Summary of Contents for FAAC 820

  • Page 1 Installation Manual 820/860 Sliding Gate System Leading the way ... Leading the way ... Leading the way ...
  • Page 2 Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 820-860 automation system • is intended to be incorporated into machinery, or to be assembled with other machinery to constitute machinery in compliance with the requirements of Directive 89/392 EEC, and subsequent amendments 91/368 EEC, 93/44 EEC and 93/68 EEC;...
  • Page 3 17) Each installation must be fitted with at least one flashing light (e.g. FAAC LAMP, MINILAMP etc.) as well as a warning plate suitably fixed to the gate, besides the safety devices as per point 16. above.
  • Page 4 These instructions apply to the following models: where: 820 EMC Z20 CR - 820 EMC - 820 EMC RF - 860 MC Z16 - 860 Ta = opening time MC - 860 MC RF - 860 EMC Z16 - 860 EMC...
  • Page 5 2. ELECTRICAL SET-UP (standard system) 0 ¸ 50 Fig. 4 820/860 operator with 0 ¸ 50 826 MPS control unit Fig. 5 Photocells accessories and the electricity supply as described in Key switch section 2. For ease of connection, ensure that the...
  • Page 6 Fig. 12 3) Rest the first rack element level on the pinion and weld the threaded pawl onto the gate as shown in Fig. 15. 4) Slide the gate manually making sure that the rack rests on the pinion. Weld the second and third pawls. 5) Place another rack element next to the first and use a section of rack to set the teeth of the two elements in phase as shown in Fig.
  • Page 7 In versions for chain and idle transmission applications, mount the Z16 or Z20 chain pinion. Proceed as follows: 4.5.1 MODEL 820 EMC - 860 MC - 860 EMC (figs. 18-19) - Insert the elastic pin in the shaft with the aid of a hammer. Fig. 21...
  • Page 8 LIMIT SWITCH / RESET PROGRAMMING BUTTON lamp to terminals 8-10 gives inverse operation. DECODER CONNECTOR 5.2.7. FAAC LAMP (terminals 11 - 12) LOW VOLTAGE TERMINAL BLOCK These are the 230 Vac terminals to which the flashing light ADL CONNECTOR must be connected.
  • Page 9 (2) 5.2.10. ELECTRONIC SAFETY DEVICE TABLE 7 LOGIC A1 (AUTOMATIC) (models 820 EMC - 860 EMC only) LOGIC A1 IMPULSES The operator is equipped with a system which cuts in when GATE STATUS...
  • Page 10 LED will light up for approximately one second to FOR AUTOMATION OF GATES WITH A MAXIMUM LENGTH OF confirm that the limit switch has been recognised. 13 m FOR MODELS 820 (Z 20 PINION) AND 10 m FOR c) release the FCA button. MODELS 860 (Z 16 PINION).
  • Page 11 Bear in mind that when For medium-low duty cycles an annual check is sufficient; this is done with model 820 the electronic anti-crushing for more intense use it is advisable to check every 6 device cuts in and stops the movement of the gate if it is months.
  • Page 12 Fig. 30 Fig. 29 Fig. 32 Fig. 31...
  • Page 13 DESCRIPTION The FAAC 820 - 860 automations are ideal for controlling vehicle access areas with medium-high transit frequencies. The 820 and 860 for sliding gates are electromechanical operators which transmit movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate.
  • Page 14 The descriptions and illustrations contained in this manual are not The descriptions and illustrations contained in this manual are not binding. FAAC reserve the right, whilst leaving the main features of binding. FAAC reserve the right, whilst leaving the main features of the main equipment unaltered, to undertake any modifi...

This manual is also suitable for:

860

Table of Contents