5.1 Basic confi guration
To perform BASIC programming:
1.
Press and hold button F; the name of the first function is
displayed.
2.
Release the button; the function value is displayed and can be
modified using the + and - buttons.
3.
Press and hold F again; the name of the following function is
displayed, and so on.
The last function St lets you choose whether to save the configuration
Y
made (
) or exit without saving (
showing the automated system status
You can go to St at any time. To exit programming,
simultaneously press F and -.

BASIC CONFIGURATION

Display
Function
cF
Barrier configuration
01
Minimum mass
06
Maximum mass
Before automated system start-up, you must
set the correct value, directly correlated to
the length of the beam and the number and
type of accessories installed. To determine
said value, refer to Tables 4 and 5 on page 25
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
Loading a different configuration
will reset the parameters to the
default values
dF
Default
Y
indicates that all values set correspond
to the defaults
no
indicates that one or more set values
are different from the defaults. Select
Y
to restore the default configuration.
Ct
Master / slave configuration
MA
Configures the board in master mode
SL
Configures the board in slave mode
For details on MASTER / SLAVE
configuration, refer to section 9.
bu
BUS accessories menu
For functions associated with this parameter
see paragraph 5.3
no
). Later, the display will resume
Default
06
Y
MA
no
Display
Function
LO
Operating logics
A
Automatic
A1
Automatic 1
E
Semi-automatic
P
Parking
PA
Automatic parking
Cn
Condo
CA
Automatic condo
C
Dead-man
CU
Custom
PA
Pause time
Is effective only if an automatic logic is chosen;
the value can be set from
one second steps. Next, the display changes
to minutes and tenths of a second (separated
by a decimal point) and time is adjusted in
10-second steps up to the maximum value
4.1
of
minutes.
e.g. if the display shows
will be 2 minutes and 50 seconds.
So
Opening speed
Adjusts the barrier opening speed.
00
Minimum speed
10
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
Sc
Closing speed
Adjusts the barrier closing speed.
00
Minimum speed
10
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
L1
Loop 1
Activating this parameter, any loop that is
connected to the Loop 1 input will serve as
an OPEN function.
Y
Loop 1 enabled
no
Loop 1 disabled
Note: Should this function be disabled, the
detection status of the loop will in any case
remain available on one of the two outputs,
if configured (see parameters
Advanced Configuration)
L2
Loop 2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
9
Default
E
20
O
59
to
sec. in
2.5
, the pause time
10
02
no
o1
o4
...
in
no

Advertisement

Table of Contents
loading

This manual is also suitable for:

B680h

Table of Contents