When this function is activated, the OPEN command during opening will stop movement.
06
no
05
If parameter
is
06
Y
If parameter
is
the system is ready for closing.
When this function is activated, the OPEN command during opening reverses movement.
06
05
If parameters
and
When this function is activated, the OPEN command during pause stops operation.
07
07
If parameters
and
When this function is activated, the OPEN command during pause causes closing.
08
07
If parameters
and
When this function is activated, the OPEN command during closing stops operation,
09
otherwise it reverses movement.
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE
10
command will stop operation
When this function is activated, the CLOSE command has priority over OPEN, otherwise
11
OPEN has priority over CLOSE.
When this function is activated, the CLOSE command commands closing when released.
12
As long as CLOSE is activated, the unit stays in closing pre-fl ashing.
When this function is activated, the CLOSE command during opening stops operation,
13
otherwise the CLOSE command commands reverse immediately or when opening is com-
pleted (see also parameter
When this function is activated, and if parameter
14
immediate closing at the end of the opening cycle (stores CLOSE). If parameters
no
are
CLOSE commands immediate closing.
When this function is activated, with the system blocked by a STOP, a next OPEN
15
moves in the opposite direction. If parameter
When this function is activated, during closing, the CLOSING SAFETIES stop and allow
16
motion to resume when they are disengaged, otherwise they immediately reverse opening.
When this function is activated, the CLOSING SAFETIES command closing when they are
17
disengaged (see also parameter
When this function is activated, and if parameter
18
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES.
When this function is activated, during closing, LOOP2 stops and allows motion to resume
19
when it is disengaged, otherwise it immediately reverses opening.
When this function is activated, LOOP2 commands closing when it is disengaged (see also
20
21
parameter
).
When this function is activated, and if parameter
21
cycle to end before executing the closing command provided by LOOP2.
When this function is activated: in case of a blackout, once electrical power has been
22
restored, if an OPEN command is not active the automated system recloses immediately.
LOOP 1 commands opening and, once completed, it closes if disengaged (useful in case
23
of vehicle backing-up with consecutive loops). If disabled, when LOOP 1 is disengaged, it
does not close.
When this function is activated, an open or close command is only carried out after
24
the safeties have been disengaged.
A.D.M.A.P. function
25
When this function is activated, the result is operation of safeties compliant with French
regulations.
When this function is activated, the CLOSING SAFETIES during closing stop and reverse
26
movement when they are disengaged, otherwise they reverse immediately.
27
DO NOT CHANGE
28
DO NOT CHANGE
29
DO NOT CHANGE
When this function is activated, the LOOP1 commands are prioritised rather than the
30
LOOP2 commands.
the system is ready for opening.
06
no
are
OPEN will have no effect during opening.
08
no
are
OPEN resets the pause time
08
no
are
OPEN resets the pause time.
14
)
13
no
is
15
no
is
18
).
20
, the CLOSE command commands
13
and
it always closes.
17
Y
is
, the unit will wait for the
Y
is
, the unit will wait for the opening
15
Y
= when opening it stops
no
= disabled
Y
= when opening it reverses
no
= disabled
Y
= when in pause it stops
no
= disabled
Y
= when in pause it closes
no
= disabled
Y
= stops
no
= reverses
Y
= active
no
= disabled
Y
= active
no
= disabled
Y
= closes when released
no
= closes immediately
Y
= CLOSE stops
no
= CLOSE reverses
Y
= closes at the end of
14
opening
no
= immediate closing
Y
= moves in the opposite
direction
no
= always closes
Y
= closes when disengaged
no
= immediate reverse
Y
=
closing
when
is disengaged
no
= disabled
Y
= closes at the end of
opening
no
= disabled
Y
= closes when disengaged
no
= immediate reverse
Y
= closes if LOOP2 is clear
no
= disabled
Y
= closes at the end of
opening
no
= disabled
Y
= active
no
= disabled
Y
= closes if LOOP1 clear
no
= disabled
Y
= active
no
= disabled
Y
= active
no
= disabled
Y
= stops and reverses when
disengaged.
no
= reverses immediately.
no
no
no
Y
= active
no
= disabled
FSW