The Installation Space; Dimensions And Clearances - Monogram ZIRS360NHLH Installation Instructions Manual

36” built-in all-refrigerators and all-freezers
Hide thumbs Also See for ZIRS360NHLH:
Table of Contents

Advertisement

Design Guide - Stainless Steel Installation

THE INSTALLATION SPACE

Water And Electrical Locations
Electrical and water supply must be located as
shown.
The Cutout Depth Must Be 24" Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24" installation depth shown. The top
case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D.
copper tubing or QuickConnect
cold water line and water connection location,
long enough to extend to the front of the unit.
Installation of an easily accessible shut-off valve in
the water line is required.
kit between the
40

DIMENSIONS AND CLEARANCES

35"
25-3/4" Stainless Steel Models
Case Width
Case Depth
*84" From
*83-1/2"
Floor to
at
Top Frame
Rear
36" Frame to
Frame Width
Depth Including Handles:
27-5/8" Stainless Steel Models
28-5/8" Professional Models
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings
between 90° and 130°.
130° Door Swing
115° Door Swing
Allow 25" minimum clearance for a full 130° door
swing. Allow 15" for pan removal.
For a 90° door swing, allow 4" minimum clearance to
a wall for framed and stainless steel models. Allow 5"
minimum clearance for professional models. If the 90°
doorstop position is used, pan access is maintained
but pan removal is restricted.
See illustration on page 42 to determine door swing
interaction with adjacent cabinets or countertops.
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 84-1/2" max. height.
Note that the top case
trim at the front is 1/2"
higher and will overlap
upper cabinetry or soffit.
Use leveling legs and
wheels for a maximum
1" height adjustment.
90° Door Swing
*
"
4
stainless and trimmed
"
models. 5
Pro models.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zifs360nhrhZifs360nhh

Table of Contents