Ordering Replacement Parts

Replacement adaptors for the Microinverter include:
Q-DCC-2: Cable Assembly, DC adaptor to MC-4
Q-DCC-5: Cable Assembly, DC adaptor to Amphenol UTX
These parts are available from your Enphase distributor.

Enphase Q Cable Planning and Ordering

The Enphase Q Cable is a continuous length of 12 AWG, double insulated, outdoor-rated cable with
integrated connectors for microinverters. These connectors are preinstalled along the Q Cable at intervals
to accommodate varying PV module widths. The microinverters plug directly into the cable connectors.
The cabling is compatible with a variety of PV racking systems. For a list of approved PV racking
systems, refer to the PV Racking Compatibility document on the Enphase website at
enphase.com/support.

Connector Spacing Options

Q Cable is available in three connector spacing options. The gap between connectors on the cable can
be 1.3 meters, 2.0 meters, or 2.3 meters. The 1.3 meter spacing is best suited for connecting PV modules
installed in portrait orientation, while the 2.0 meter and 2.3 meter spacing allows you to install 60-cell and
72-cell PV modules in landscape orientation, respectively.

Cabling Options

Ordering options include:
Cable Model
Q-12-10-240
Q-12-17-240
Q-12-20-200
The Cabling System is flexible enough to adapt to almost any solar design. To determine the cable type,
you need, apply the following considerations:
When mixing PV modules in both portrait and landscape orientation, you may need to
transition between cable types. See the preceding table for available cable types.
To transition between cable types, install a Field Wireable connector pair.
In situations where portrait modules are widely spaced, you may need to use landscape
spaced cables for the portrait-oriented PV modules and create loops of excess cable, if
needed.
WARNING: Do not form loops smaller than 12 cm (4.75") in diameter.
28
Connector spacing
PV module orientation
1.3m (50")
Portrait
2.0m (78")
Landscape (60-cell)
2.3m (90")
Landscape (72-cell)
© 2018 Enphase Energy Inc. All rights reserved.
IQ 7 / IQ 7+ / IQ 7X Micro Installation and Operation
Connector count per box
240
240
200
141-00043-02