enphase Q 7 Micro Installation And Operation Manual page 37

Microinverters
Table of Contents

Advertisement

9
Maximum
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
9
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.
37
IQ7X-96-2-US Microinverter Parameters
Miscellaneous Parameters
Features and Specifications
Pairs with 96-cell PV modules
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 (or Amphenol H4 UTX with additional Q-DCC-5 adaptor)
1.08 kg (2.38 lbs.)
NEMA type 6 / outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
Power line
enphase.com/warranty
CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC
Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-
01
This product is UL Listed as PV Rapid Shut Down Equipment and
conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-
2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC
conductors, when installed according manufacturer's instructions.
The DC circuit meets the requirements for ungrounded PV
arrays in NEC. Ground fault protection (GFP) is integrated into
the class II double insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options require
an Enphase IQ Envoy
The DC connector has been evaluated and approved for use
as the load-break disconnect required by NEC 690.
The AC connector has been evaluated and approved for use as
the load-break disconnect required by NEC 690.
© 2018 Enphase Energy Inc. All rights reserved.
IQ 7 / IQ 7+ / IQ 7X Micro Installation and Operation
%
97.5
96.5
%
99.5
%
C
-40
mW
C
-40
6 mm (1/4") mounting hardware: 5 N m (45 - 50 in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 - 85 in-lbs.)
When using UL 2703 mounting hardware, use the
manufacturer's recommended torque value
12
10
5
+60
50
+85
141-00043-02