Download Print this page

Omega CND3 Series User Manual page 18

Hide thumbs Also See for CND3 Series:

Advertisement

 Limits of temperature ranges
Different input sensors have different application ranges (e.g.: J type factory setting is -100 ~ 1200℃), adjust parameters
limit) /
(lower limit) in Initial Setting Mode.
If lower limit is altered to 0 and upper limit is altered to 200, the limit function will be enabled in the following conditions:
When setting the SV value, the limits may set for 0~200℃
In ON-OFF, PID, FUZZY and Self-Tuning control conditions, the control output will be forced to shut off if the PV value exceeds the
upper/lower limit. (Alarm output is still normal)
 User Setting of F1, F2 function keys
In the Operation Mode, (PV/SV display mode), pressing a function key more than 3 seconds will prompt you to the setting of the following
functions; press
keys to make a selection.
Function
When in a screen other than the PV/SV display mode, pressing F1/F2 key continuously may save the setting, to quickly
switch the menu screen
MENU
(When the screen shows KEY SAVE, the menu screen is saved)
AT
Selecting this function, F1 / F2 button can be used for quick ON / OFF operation of AT function
R-S
Selecting this function, F1 / F2 button can be used to switch between RUN/STOP status.
PROG
Selecting this function, F1 / F2 button can be used to switch between RUN/HOLD status.
ATMT
Selecting this function, F1 / F2 button can be used to switch between PID and MANUAL control mode
ALRS
Selecting this function, F1 / F2 button can be used to reset Alarm Hold status.
SV2
Selecting this function, F1 / F2 button can be used to switch between SV1/SV2.
For disabling F1/F2 function, please select 【MENU】 without saving any menu screen.
 Edit a self-defined Menu Screen
Hidden MENU setting: Lock all buttons by adjusting parameter
and
keys for 3 seconds to display
table for details. Select "Hide" to hide the Menu.
Menu Layer setting: Lock all buttons by adjusting parameter
and
keys for 3 seconds to display
table for details. Selectable items are NOR= display layers; ADJ= adjust layers; SET= set layers.
Menu layer reset: Lock all buttons by adjusting parameter
keys for 3 seconds to display
to reset all menu layers to default setting.
RUN layer
Menu No.
Corresponding menu
M101
M102
M103
M104
M105
M106
M107
M108
M109
M110
M111
M112
M113
M114
Description
to
, and enter Password-1. The screen will show menu number
to
, and enter Password-2. The screen will show menu number
to
, and enter Password-3. The screen displays
Adjust layer
Menu No.
Corresponding menu
M201
M202
M203
M204
M205
M206
M207
M208
M209
M210
M211
M212
M213
M214
in 【Operation Mode】. At the same time press
in 【Operation Mode】. At the same time press
in 【Operation Mode】. At the same time press
(Level reset) parameters, select
Menu No.
M301
M302
M303
M304
M305
M306
M307
M308
M309
M310
M311
M312
M313
M314
(upper
, see the following
, see the following
and
Setting layer
Corresponding menu
16

Advertisement

loading

This manual is also suitable for:

Cn16d3-r-ac