limit of input)*(Remote input value - lower limit of Remote input)/( higher limit of Remote input - lower limit of Remote input) –
Remote lower limit of input)
Set parameter
Note: This option is only available when a Remote board is inserted. If the Remote type is of analog current, the JP in the
Remote board must be shorted (using a short cap). If the Remote type is of analog voltage, ensure the JP is open.
Remote type setting: Set type of the Remote input (including analog current 0~20 m A,4~20m A; analog voltage 0~5V, 1~5V,
0~10V)Set Remote input type by parameter
Remote positive/negative slope setting: Set corresponding value of Y position by parameter
Mode】, e.g.: xYxx (Y can be 0 or 1; 0: positive; 1: negative).
Remote compensation adjustment: input corresponding lower limit of analog signal at the Remote end, set Remote
compensation adjustment by parameter
Remote gain adjustment: input corresponding upper limit of analog signal at the Remote end, set Remote compensation
adjustment by parameter
Remote lower limit: Setting Remote lower limit by parameter
Remote higher limit: Setting Remote higher limit by parameter
How to setting current input
Short the Jumper on Remote board.
Remote board
Jumper
Normal Input (Factory Setting)
 Control Mode Setting
There are 4 control modes; ON-OFF, PID, FUZZY and MANUAL.
ON-OFF Mode: For heating output, the output is off when input is greater than the setting value; output is on when input is smaller
than (setting value – adjustment sensitivity setting value). For cooling output, the output is on when the input is greater than
(setting value + adjustment sensitivity setting value); output is off when input is smaller than the setting value. If one of 2 outputs is
set for heating and the other for cooling, a non-action zone can be set as follows.
Heating sensitivity
adjustment
Heating
(Output ON-OFF control of both actions)
Set parameter
Set adjustment sensitivity: Set adjustment sensitivity by parameter【Regulation Mode】 to
(output 2)
Setting of DeadBand of both outputs: Set DeadBand by parameter
to
in 【Initial Setting Mode】
in【Regulation Mode】
Cooling sensitivity
adjustment
DeadBand
Cooling
Set value
to
in 【Initial Setting Mode】
in 【Initial Setting Mode】
in【Regulation Mode】
in【Regulation Mode】
in【Regulation Mode】
Current Input (4 ~ 20mA, 0 ~ 20mA)
in 【Regulation Mode】
in【Initial Setting
(Output 1),
12