First Alert FA162C Installation Instructions Manual page 77

2-partitioned
Hide thumbs Also See for FA162C:
Table of Contents

Advertisement

The following describes each format in greater detail.
3+1 and 4+1 Standard Formats
3+1 and 4+1 Expanded Formats
4+2 Format
Ademco Contact ID
Reporting Format
Where:
SSS or
SSSS =
T t =
Bb =
EA C =
LL B =
O =
Comprise a 3- (or 4-) digit subscriber number and a single digit
report code (e.g. Alarm, Trouble, Restore, Open, Close, etc).
Comprise a 3- (or 4-) digit subscriber number, and a two-digit
report code. The first digit is displayed on the first line, followed
by a second line where the first digit is repeated 3 (or 4) times
and followed by the second digit. This is the ÒexpandedÓ digit.
Comprises a 4-digit subscriber number and 2-digit report code.
Comprises a 4-digit subscriber number, 1-digit event qualifier
("new" or "restore"), 3-digit event code, 2-digit Partition No., and
3-digit zone number, user number, or system status number (see
the following page).
Report
Alarm
Trouble
Bypass
AC Loss
Low Batt
Open
Close
Test
Restore
Alarm
AC Restore
LoBat Res.
Trouble Res.
Bypass Res.
Subscriber ID
A =
Alarm CodeÐ1st digit
Z =
Typically Zone Number*Ð2nd digit
Trouble Code (1st & 2nd digits)
Bypass Code (1st & 2nd digits)
AC Loss Code (1st & 2nd digits)
Low Battery Code(1st & 2nd digits)
Open CodeÐ1st Digit
*Zone numbers for: [ ] & [#], or [B] = 99
3+1/4+1
3+1/4+1
Standard
Expanded
SSS(S) A
SSS(S) A
AAA(A) Z
SSS(S) T
SSS(S) T
TTT(T) t
SSS(S) B
SSS(S) B
BBB(B) b
SSS(S) E
SSS(S) E
EEE(E) A C
SSS(S) L
SSS(S) L
LLL(L) L B
SSS(S) O
SSS(S) O
OOO(O) U
SSS(S) C
SSS(S) C
CCC(C) U
SSS(S) G
SSS(S) G
GGG(G)g
SSS(S) R
SSS(S) R
RRR(R) Z
SSS(S) R A
SSS(S) R A
R A R A R A (R A )A c
SSS(S) R L
SSS(S) R L
R L R L R L (R L )L B
SSS(S) R T
SSS(S) R T
R T R T R T (R T )t
SSS(S) R B
SSS(S) R B
R B R B R B (R B )b
C =
U =
Gg =
R =
R T t =
R B b =
R A A C =
R L L B =
[1] + [ ], or [A] = 95
[3] + [#], or [C] = 96
–77–
4+2
SSSS AZ
SSSS Tt
SSSS Bb
SSSS EA C
SSSS LL B
SSSS OU
SSSS CU
SSSS Gg
SSSS RZ
SSSSR A A c
SSSS R L L B
SSSS R T t
SSSS R B b
Close CodeÐ1st Digit
User Number (in hex)
Test Code (1st & 2nd digits)
Restore Code (Alarm)
Restore Code (Trbl)1st & 2nd digits
Restore Code (Byps)1st & 2nd digits
Restore Code (AC)1st & 2nd digits
Restore Code (Bat)1st & 2nd digits
Duress = 92
Tamper = 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FA162C and is the answer not in the manual?

Questions and answers