Type 06
24-hour Silent Alarm
Type 07
24-hour Audible Alarm
Type 08
24-hour
Auxiliary Alarm
Type 09
Supervised Fire
(With Verification on
Zone 1)
Type 10
Interior w/Delay
Type 20
ArmÐStay
Type 21
ArmÐAway
Type 22
Disarm
Type 23
No Alarm Response
Type 24
Silent Burglary
NOTE: All of the zone types described are available for the wireless portion of the system, if used.
This zone type sends a report to the Central Station but provides no keypad
display or sounding. This zone type is usually assigned to a zone containing
an Emergency button.
This zone type sends a report to the Central Station, and provides an alarm
sound at the keypad, and an audible external alarm. This zone type is usually
assigned to a zone that has an Emergency button.
This zone type sends a report to Central Station and provides an alarm sound
at the keypad. (No bell output is provided). This zone type is usually
assigned to a zone containing a button for use in personal emergencies, or to a
zone containing monitoring devices such as water or temperature sensors, etc.
This zone type provides a fire alarm on short circuit and a trouble condition
on open circuit. The bell output will pulse when this zone type is alarmed.
This zone type is always active and cannot be bypassed. This zone type can
be assigned to a control panel basic wired zone, any zone in a wired
zone expansion module, or wireless zones. When used with zone 1 on
the panel, 2-wire smoke detectors can be used. For an explanation of the
ÒverificationÓ function, refer to the ÒOperationÓ paragraph in a previous
section titled 2-Wire Smoke Detector Installation.
Note:ÊÊOnly hardwired zone 1 can be programmed as a fire zone in UL
ÊÊÊÊÊÊÊÊÊÊÊ installations. However, any wireless zone can be used as a fire
ÊÊÊÊÊÊÊÊÊÊÊÊzone.
This zone type gives entry delay #1 (using the programmed entry time), if
tripped when the panel is armed in the Away mode. Entry delay begins
whenever sensors in this zone are violated, regardless of whether or not an
entry/exit delay zone was tripped first. No entry delay is provided if tripped
when the panel is armed in the Maximum mode. Exit delay is present for any
arming mode. This zone type is bypassed when the panel is armed in
the Stay or Instant modes.
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the STAY mode when the
zone is activated. Pushbutton units send zone number as a user number to
central station when arming or disarming.
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the AWAY mode when the
zone is activated. Pushbutton units send zone number as a user number to
central station when arming or disarming.
This is a special-purpose zone type used with 5800 series wireless pushbutton
which will result in disarming the system when the zone is activated.
This zone type can be used on a zone when an output relay action is desired,
but with no accompanying alarm (e.g., lobby door access).
This zone type provides an instant alarm, with NO audible indication at any
keypad or external sounder, if the zone is faulted when the system is armed
in the AWAY, STAY, INSTANT, or MAXIMUM modes. This zone type is
usually assigned to all sensors or contacts on exterior doors and windows
where bells and/or sirens are NOT desired. A report is sent to the Central
Station.