RESTORE
REPORT CODES
( 70Ð 76)
67
RF XMTR LOW BATTERY REPORT CODE
This is sent in the event that a wireless transmitter low battery
condition exists. (See box)
68
CANCEL REPORT CODEÊÊÊÊ(See box on previous page.)ÊÊ
This is sent upon disarming of the system after an alarm condition
was reported.
70
ALARM RESTORE REPORT CODE, 1st DIGIT
This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd digit
of the zone alarm report code programmed in field 56, if expanded or
4+2 reporting is selected.
71
TROUBLE RESTORE REPORT CODE
See box. This is sent when a trouble in a zone is restored.
72
BYPASS RESTORE REPORT CODE
See box. This is sent when a zone that has been bypassed is un-
bypassed.
73
AC RESTORE REPORT CODE
This is sent when AC power has been restored after an AC power
outage. See box. Reports with Partition 1 Subscriber No.
74
LOW BAT RESTORE REPORT CODE
This is sent when a system low battery condition is restored to
normal. See box on previous page. Reports with Partition 1
Subscriber No.
75
RF XMTR LOW BATTERY RESTORE CODE
See box. This is sent when a transmitter that previously sent in a low
battery message has sent a message indicating it no longer has a low
battery condition.
76
TEST RESTORE REPORT CODE
This is sent when the test mode is exited. See box. Reports with
Partition 1 Subscriber No. A restore code entered
here will cause a restore message to be sent when Test mode is exited.
89
EVENT LOG 80% FULL REPORT CODE
If an Event Logging selection is made in field
sent to the central station receiver when the log is 80% full. If the log
becomes full, a new message will overwrite the oldest message in the
log. Note: Aside from the selection made by the installer in field 90,
all control and readout from the log is accomplished via the
Downloader.
90
EVENT LOGGING
0 = No event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of entries) Example: ÊTo select
ÒAlarm/Alarm RestoreÓ, and ÒOpen/CloseÓ, enter 9 (1 + 8); to select
all events , enter #15. Press [#] first to enter 2-digit options.
The default of Ò3Ó = alarm/alarm restore (1) plus trouble/trouble
restore (2).
–54–
ÊÊ0ÊÊ|ÊÊ0ÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
Ê ÊÊ0ÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
ÊÊ0ÊÊ|Ê0ÊÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
ÊÊ0ÊÊ|Ê0ÊÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
ÊÊ0ÊÊ|ÊÊ0ÊÊ
90, a message can be
Ê ÊÊ3ÊÊ