5.8.1

Temperature sensor

The following temperature sensor variants are available:
Installation site
Figure 6 : Installation site of oven sensor / bench sensor / combined bench sensor
Oven sensor - Temperature
Bench sensor for temperature
Combined bench sensor for temperature and humidity
For all sensors
Installation instructions Sauna control Series FCUxx00 / Version V 2.27
Oven sensor for temperature (FCU-SENSOR-OVEN-A)
Bench sensor for temperature (FCU-SENSOR-BENCH-A)
Combined bench sensor for temperature and humidity
(FCU-SENSOR-HUMIDITY-BENCH-A)
I.) Floor-standing- or Wall-mounted heater
Unless a different position is specified by the oven manufacturer, install it on the wall
behind the sauna oven (centre sauna oven), 20 cm below the ceiling.
II.) Underbench heater
1-Sensor-System-U1: Unless a different position is specified by the oven
manufacturer, install it on the wall behind the sauna oven (centre sauna oven), 20
cm below the ceiling and additionally install one STB (Safety-Temperature-Limiter)
U2 5cm below the grating of the airshaft.
2-Sensor-System-U2: Unless a different position is specified by the oven
manufacturer, install it on the wall behind the sauna oven (centre sauna oven), 5cm
below the grating of the airshaft.
Install the bench sensor at shoulder height of the topmost bench:
I.) on the opposite side of the oven (S2)
II.) same side, offset to the Underbench oven (U1) or adjacent wall.
This position for the sensor is only a recommendation for standard cabins.
Attention: The system installer has to consider cabin-specific conditions, such as
the position of the steam outlet, the supply and outlet air, the door (s), the shape of
the ceiling, etc., and mount the sensor at the appropriate place for this cabin!.
Install the combined sensor for temperature and humidity like the bench sensor.
Ensure unrestricted air circulation.
Do not install the sensors in the immediate vicinity of the door or a window.