Installation; Esd Protection; Installation Of Sauna Control Device Fcuxxxx; Installation Of The Operating Control Of Fcuxxxx-Design - Fasel Elektronik FCU 00 Series Installation Instructions Manual

Table of Contents

Advertisement

5

Installation

5.1

ESD protection

5.2

Installation of sauna control device FCUxxxx

Installation
The sauna control device should be installed sideways, above and below at a distance
of at least 5 cm from the walls or other equipment. There should be a distance of 10 cm
between other electrical devices.
The sauna control device must be mounted on a closed surface (no grid structure) so
that no electrical parts can be touched through the openings in the rear panel.
The control unit must be mounted so that it is at any time accessible! (e.g. for service,
wear parts, fuses, etc.)
5.3

Installation of the operating control of FCUxxxx-Design (-.....)

Installation
The operating control can be installed maximum 100 m away from the basic control
device.
Installation instructions Sauna control Series FCUxx00 / Version V 2.27
– ATTENTION!
– Note ESD protection!
– Do not touch on electrical parts because of ESD protection reasons.
When assembling only touch the circuit board at the plastic case or at
the edge of the board.
– Also only touch the connection cable to the circuit board, on the
connector. Thereby do not touch the contact surfaces.
Therefore:
– Take appropriate protections. Touch a grounded piece of metal as a
minimum protection.
Note!
At FCUxxxx-Design-Glas the main switch of the control unit must be
accessible.
ATTENTION!
Damage or malfunction of the operating control FCUxxxx-Design-
Glas by steam, humidity or water!
– Therefore:
– It must be ensured, that neither steam, humiditiy or water can occur
at or in the keyboard.
Installation
15