Standard reactors can be used on GV3000/SE drives with carrier frequency settings up to 8 kHz.
All reactors listed are UL-recognized (UL-506 File #E53094) and CSA certified (CSA File #LR29753).
3-8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 3.10 – Recommended Motor Lead Lengths for Reliance Inverter Duty Motors
GV3000/SE
HP Rating
Filter Type
1 to 2
3 to 5
7.5 to 10
15 to 20
None
25 to 60
75 to 100
125 to 150
200 to 400
1 to 2
3 to 5
7.5 to 10
15 to 20
A 5% reactor/filter
at the drive.
25 to 60
75 to 100
125 to 150
200 to 400
Table 3.11 – Compatible Reactors
GV3000/SE
480 Volt
HP Rating
5% Reactor
1
RL-00202
2
RL-00403
3
RL-00403
5
RL-00803
7.5
RL-01203
10
RL-01803
15
RL-02503
20
RL-03503
25
RL-03503
30
RL-04503
40
RL-05503
Maximum Lead Length in Feet with
460 VAC Motor
Carrier Frequency
2 kHz
4 kHz
500
500
500
500
750
500
800
500
800
500
800
500
800
500
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
GV3000/SE
480 Volt
HP Rating
5% Reactor
50
RL-08003
60
RL-08003
75
RL-10003
100
RL-13003
125
RL-16003
150
RL-20003
200
RL-25003
250
RL-32003
300
RL-40003
350
RL-50003
400
RL-50003
GV3000/SE AC Drive Hardware Reference, Version 6.06
8 kHz
500
500
500
500
500
500
500
1000
1000
1000
1000
1000
1000
1000
1000
1000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gv3000se5v4160Gv300088490-188490-288490-3

Table of Contents