This function just supports above firmware version 3.00.
 Example:
Command: P3040000000000000000<CR>
Change the CAN baud rate=125K and acceptance code
0x00000000, acceptance mask 0x00000000 into the CAN
Converter module. When CAN Converter module was rebooted,
the CAN parameter will be recovered to the previous setting.
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 47