4.7 P0BBDSPAE[CHK]<CR>
 Description: Change the RS-232/RS-485/RS-422/USB
 Syntax: P0BBDSPCE[CHK]<CR>
P0
BB
D
S
P
C
E
Table: RS-232/RS-485/RS-422/USB baud rate list
BB
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 41
configurations of the CAN Converter module. Module
will be rebooted after saving these parameters into
EPROM successfully.
Command character
RS-232/RS-485/RS-422/USB Baud rate
Data bit
0 = 5 bits Data formation
1 = 6 bits Data formation
2 = 7 bits Data formation
3 = 8 bits Data formation
Stop bit (0=1 stop bit, 1=2 stop bits)
Parity (0=None, 1=Odd, 2=Even)
Checksum (0=No, 1=Yes)
Error Response (0=No, 1=Yes);
110 bps baud rate of RS-232
150 bps baud rate of RS-232
300 bps baud rate of RS-232
600 bps baud rate of RS-232
1200 bps baud rate of RS-232
2400 bps baud rate of RS-232
4800 bps baud rate of RS-232
9600 bps baud rate of RS-232
19200 bps baud rate of RS-232
38400 bps baud rate of RS-232
57600 bps baud rate of RS-232
115200 bps baud rate of RS-232
230400 bps baud rate of RS-232, only for I-7565 and tM-7530
460800 bps baud rate of RS-232, only for I-7565
921600 bps baud rate of RS-232, only for I-7565