4.10 P3SBCCCCCCCCMMMMMMMM [CHK]<CR>
 Description: Change the CAN configuration of CAN Converter
 Syntax: P3SBCCCCCCCCMMMMMMMM[CHK]<CR>
P3
S
B
CCCCCCCC
MMMMMMM
B
0
10K baud rate of CAN
1
20K baud rate of CAN
2
50K baud rate of CAN
3
100K baud rate of CAN
4
125K baud rate of CAN
5
250K baud rate of CAN, I-7530-FT does not support
6
500K baud rate of CAN, I-7530-FT does not support
7
800K baud rate of CAN, I-7530-FT does not support
8
1000K baud rate of CAN, I-7530-FT does not support
9
83.3K baud rate of CAN, I-7530-FT does not support
 Response: A valid command will let the module to apply the CAN
Note:
It is necessary to enable the "Error Response" function in the CAN
Converter Utility, in order to receive Syntax and/or communication
error information at the host PC. This command does not support
user-defined CAN baud rate function. About CAN filter setting, please
refer to section 3.2.
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 46
module.
This
configuration parameter into SRAM. When the module
is rebooted, the CAN configuration will recover the
previous setting.
Command character
CAN Specification 2.0A/2.0B
CAN Baud rate
CAN filter acceptance code
CAN filter acceptance mask
Table: CAN baud rate list
configuration parameters.
Invalid command: ?<Error Code><CR>