4.5 S[CHK]<CR>
 Description: Read the CAN Converter CAN Baud Rate and error
 Syntax: S[CHK]<CR>
S
 Response: Valid Command: !CFFTTRRO[CHK]<CR>
!
Delimiter for valid command
C
current baud rate setting of CAN
FF
CAN register
TT
CAN transmit error counter
RR
CAN receive error counter
O
CAN or RS-232/RS-485/RS-422/USB FIFO Overflow flag
Note:
It is necessary to enable the "Error Response" function in the CAN
Converter Utility, in order to receive Syntax and/or communication
error information at the host PC. Furthermore, all response results
are shown in the ASCII format. Users need to make an ASCII to hex
format transformation in order to understand what the meaning is
based on the following table.
AsciiToHex(C)
0
1
2
3
4
5
6
7
8
9
A
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 38
flag message.
Command character.
Invalid command: ?<Error Code>[CHK]<CR>
Table: CAN baud rate list
10K baud rate of CAN
20K baud rate of CAN
50K baud rate of CAN
100K baud rate of CAN
125K baud rate of CAN
250K baud rate of CAN
500K baud rate of CAN
800K baud rate of CAN
1000K baud rate of CAN
83.3K baud rate of CAN
User-defined baud rate of CAN
Description