4.4 EIIIIIIIIL[CHK]<CR>
 Description: Send or receive an extended CAN remote frame.
 Syntax: EIIIIIIIIL[CHK]<CR>
E
IIIIIIII
L
 Response: Valid command: No response
Note:
It is necessary to enable the "Error Response" function in the CAN
Converter Utility, in order to receive Syntax and/or communication
error information at the host PC.
 Example:
Command: E010156786<CR>
Send a CAN message with an extended remote frame.
ID=01015678, DLC=6.
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 37
Stands for the extended (2.0B) CAN remote frame.
29 bits Identifier (00000000~1FFFFFFF)
Data length (0~8)
Invalid command: ?<Error Code><CR>