Converting From Previous Models - Omron SYSMAC CS1W-ETN21 Operation Manual

100base-tx ethernet units construction of networks
Hide thumbs Also See for SYSMAC CS1W-ETN21:
Table of Contents

Advertisement

Converting from Previous Models

Abnormal Execution

2-11 Converting from Previous Models

54
$
ping 130.25.36.8
PING 130.25.36.8: 56 data bytes
←Enter Ctrl+C Key to cancel.
––––130.25.36.8 PING Statistics––––
9 packets transmitted, 0 packets received, 100% packets loss
$
Refer to operating system documentation for your host computer for details
about using the host computer's PING command.
The specifications for these Ethernet Units (CS1W-ETN21 and CJ1W-ETN21)
are compatible with those for previous models (CS1W-ETN01/ETN11 and
CJ1W-ETN11), so previous models being used with existing equipment can
be easily replaced by the new models. Many of the specifications for the new
Ethernet Units have been expanded, however, so there will be a number of
limitations if the Unit is simply replaced.
In particular, the CPU Bus Unit System Setup Area is formatted for the previ-
ous models, so there is no way to make the settings for the expanded specifi-
cations.
To remove these limitations, it is necessary to change the CPU Bus Unit Sys-
tem Setup format from "ETN11 mode" to "ETN21 mode." Refer to Changing
the CPU Bus Unit System Setup Area Format below for instructions on how to
make the change.
If the format change is from ETN11 mode to ETN21 mode, then there will be
no effect on previous applications. If the change is from ETN21 mode to
ETN11 mode, however, then certain limitations will go into effect.
The following table shows the limitations that apply when operating in ETN11
mode.
Item
Baud rate
Subnet mask
FINS node address setting range
IP address conversion: Automatic
generation method
TCP keep-alive
FINS/TCP
TCP socket services
FTP server function
; Executes PING command
Specifications in ETN11 mode
• Automatic detection (100Base-TX or
10Base-T)
• CIDR is not used.
• Operation is performed with the default net-
work mask if the subnet mask specification is
less than the network mask for each class.
• 1 to 254
• Dynamic only
• No time setting (Uses default setting)
• Server only for all connections (Uses default
setting)
• Socket option (keep-alive setting): Yes
• Number of Bytes Received at TCP Socket
Nos. 1 to 8: Yes
• Data Received Flag: Yes
• Socket high-speed option: No
• Port No. setting: No (Uses default setting)