DESCRIPTION
This portable, submersible utility pump is designed for automatic
use in water. The units are equipped with a 9 ft. 3-prong grounding
type power cord. The provided discharge adapter can be used for
convenient attachment to a garden hose.
UNPACKING
Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, contact customer service at 1-800-237-0987.
READ & FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS — DO NOT DISCARD
SAFETY GUIDELINES
This manual contains information that is important to know
and understand. This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help recognize this
information, observe the following symbols.
Danger indicates an imminently hazardous
situation which, if NOT avoided, WILL result in death or
serious injury.
Warning indicates a potentially hazardous
situation which, if NOT avoided, COULD result in death
or serious injury.
Caution indicates a potentially hazardous
situation which, if NOT avoided, MAY result in minor or
moderate injury.
Notice indicates important information, that if
NOT followed, MAY cause damage to equipment.
This is the safety alert symbol. It is used to alert you to potential
bodily injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
NOTE: Note indicates information that requires special attention.
GENERAL SAFETY INFORMATION
CALIFORNIA PROPOSITION 65
This product or its power cord may contain
chemicals, including lead, known to the State of
California to cause cancer and birth defects or other reproductive harm. Wash
hands after handling.
GENERAL SAFETY
Read the manual(s) included with this product
carefully. Be thoroughly familiar with the controls
and the proper use of the equipment. Follow all
instructions.
Only persons well acquainted with these rules of safe operation
should be allowed to use the unit.
Keep away from children!
Risk of fire, explosion and/or death!
death! Pump is NOT rated for use with
flammable/combustible liquids, vapors or dusts. Do NOT pump
liquids that are NOT clear. Failure to follow these instructions will
result in bodily injury or death.
© 2016, WAYNE/Scott Fetzer Company.
Auto On-Off Water Removal Portable Pump
Please read and save these instructions. This manual contains important Safety Warnings and Operating Instructions. You will need to refer to
it before attempting any application or maintenance. Always keep this manual with the unit so that it will be easily accessible. Failure to read
and follow these warnings and instructions could result in property damage, serious injury or death.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
OPERATING INSTRUCTIONS & PARTS MANUAL
Risk of electric shock. This pump
has NOT been tested for use in
swimming pool or marine areas. NEVER place pump in pools
while people are in the water. Failure to follow COULD result in
death or serious injury.
Risk of electric shock! Do NOT
handle pump with wet hands or when
standing in water or on a damp surface. Failure to follow COULD
result in death or serious injury.
Electric shock hazard! For installation
by a qualified electrician only. GFCI receptacles will
provide protection against line to ground faults only. The ground fault receptacle does
NOT limit the magnitude of fault current and will NOT prevent an electrical shock.
1. Wear safety glasses at all times when working
with pumps.
2. The unit MUST be plugged into a GFCI. For
installation by a qualified electrician only.
3. Damage to the power cord or discharge hose may occur.
Use the handle supplied on the pump.
APPLICATION AND OPERATION
Do NOT use pump if any part of the housing
switch or probe is cracked, broken, or missing.
Always disconnect
electric supply before
attempting to install, service, relocate, or perform
any maintenance. If the power source is out of
sight, lock and tag in open (off) position to
prevent unexpected power application. Failure to do so could result in fatal
electrical shock!
Electric shock hazard. Use only
Underwriters Laboratories (UL)-
listed extension cord with #16 gauge or larger wire that is
labeled for outdoor use. Use polarized grounding type plugs
only. Polarized plugs have one blade slightly wider than the
other and can only be inserted one way into the outlet. Do NOT handle plug
connector near water. Failure to follow these instructions will result in serious
injury or death.
This unit is NOT designed for use
as a sump pump or in sump
applications. This unit is NOT designed for use in septic tanks or
underground vaults to pump raw sewage or effluents. NEVER use
in hazardous or explosive locations.
1. This pump has been designed with 1-1/4 in. NPT discharge
connection size. Attach pipe or fitting to the discharge or use
the supplied garden hose adapter. Thread the female end of the
garden hose to the male end of the elbow.
2. Be certain to use a hose washer (not included) on the garden
hose for correct pump operation.
EEAUP250
3539 03-001 1/16

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 57729-WYN1

  • Page 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2016, WAYNE/Scott Fetzer Company. 3539 03-001 1/16 For parts, product & service information...
  • Page 2: Maintenance And Troubleshooting

    Operating Instructions and Parts Manual APPLICATION AND OPERATION (CONTINUED) 3. For best pump performance, unwind the hose before starting the pump. This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction. 4.
  • Page 3: Troubleshooting Chart

    EEAUP250 MAINTENANCE AND TROUBLESHOOTING PUMPING HEIGHT When water is pumped to an elevated position, any volume that has not (CONTINUED) reached the discharge outlet can flow back through the pump when the pump shuts off. This back-flow can cause the water level in small IMPELLER PLATE areas to rise enough to re-start the pump.
  • Page 4: Limited Warranty

    Limited Warranty For one year from the date of purchase, WAYNE Water Systems Division ("WAYNE Pumps") will repair or re place, at its option, for the original purchaser any part or parts of its Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or work man ship.
  • Page 5 Ceci aidera à retirer tous les instructions entraînera des blessures corporelles ou pertes de vies. RAPPEL: Garder la preuve d’achat datée aux fins de garantie! Il faudrait l'attacher à ce manuel ou la ranger en lieu sûr. © 2016, WAYNE/Scott Fetzer Company. 5 Fr...
  • Page 6: Maintenance Et Dépannage

    Manuel de pièces et mode d'emploi APPLICATION ET FONCTIONNEMENT (suite) entortillements ou les coudes du tuyau et laissera l'appareil pomper avec moins de restriction. 4. Placer la pompe sur une surface dure, à plat dans l'eau. Ne pas placer la pompe directement sur les surfaces de boue ou de sable. Ceci bloquera le grillage d'admission.
  • Page 7 EEAUP250 MAINTENANCE ET DÉPANNAGE (SUITE) NETTOYER LES DÉBRIS À PLAQUE D’IMPULSEUR L'INTÉRIEUR DU VIS DE BASE (4) CAPTEUR TAMIS D'ENTRÉE/ BASE TROU Figure 3 - Retirer les débris du capteur D'AMORÇAGE EN REPLAÇANT LA BASE (TAMIS D'ENTRÉE), HAUTEUR DE POMPAGE S'ASSURER QUE LES QUATRE (4) TAMIS «...
  • Page 8: Garantie Limitée

    Garantie limitée Pendant un an à compter de la date d’achat, WAYNE Water Systems Division (« Wayne Pumps ») va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de ses pompes à eau (« Produit ») déterminées défectueuses après examen par Wayne, en termes de matériaux ou de fabrication.
  • Page 9: Pautas De Seguridad

    RECORDATORIO: conserve su prueba de compra fechada para la garantía. Adjúntela a este manual o archívela para conservarla de forma segura. © 2016, WAYNE/Scott Fetzer Company. 9 Sp...
  • Page 10 Manual de instrucciones de funcionamiento y piezas de repuesto APLICACIÓN Y FUNCIONAMIENTO (continuación) 3. Para un mejor rendimiento de la bomba, desenrosque la manguera antes de encender la bomba. Esto ayudará a eliminar cualquier pliegue o acodamiento en la manguera y permitirá...
  • Page 11 EEAUP250 MANTENIMIENTO Y RESOLUCIÓN DE PROBLEMAS (continuación) LIMPIE LOS DESECHOS QUE SE ENCUENTRAN TORNILLOS DENTRO DEL SENSOR PLACA DEL IMPULSOR DE LA BASE (4) REJILLA DE ENTRADA/BASE Figura 3 – Quite los desechos del sensor ALTURA DE BOMBEO ORIFICIO DE CEBADO Cuando se bombea el agua a una posición elevada, cualquier volumen que no haya llegado a la salida de descarga puede volver a fluir por CUANDO VUELVA A COLOCAR LA BASE (REJILLA...
  • Page 12 Garantía limitada Durante un año a partir de la fecha de compra, WAYNE Water Systems Division (“WAYNE Pumps”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas de agua (“Producto”) que después de un examen sean halladas por Wayne como defectuosas en su material o mano de obra.

This manual is also suitable for:

Eeaup250

Table of Contents