Troubleshooting - ElectrIQ P12CE-V2 User Manual

12,000 btu portable air conditioner
Table of Contents

Advertisement

Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate
the warranty and may cause bodily harm.
Trouble
The unit does
not work
The unit does
not seem to
perform.
The unit is loud
Compressor
does not work
Remote control
doesn't work
E0
E2/E4
If the above solutions do not resolve the problem please contact the service centre.

TROUBLESHOOTING

Reason
No power supply
Water-full indicator illuminated
Timer function is active
Room temperature too low or too
high
In direct sunlight
Windows or doors open.
Large amount of people or a heat
source in the room.
Filter is very dirty
Air inlet or air outlet is blocked
Room temperature is lower than
setting temperature
The unit is not put on flat surface
Overheating protection is active
Operating distance is too far.
Control panel has not received the
signal from remote control.
The batteries are flat
Room temperature abnormal or
there
is
electrical
temperature sensor
Water tank is full inside the
machine
Power-on and turn on the unit.
Drain the internal water tank
Cancel Timer function
Use
only
between 7-35℃
Draw the curtains, UV affects RC
Close windows and turn on another air
conditioner
Clean or change the air filter
Clear out debris
Change the setting temperature
Put the unit on flat and hard surface
Check venting.
Restart the unit after 5 minutes when
compressor has cooled
Move remote control closer to the unit
and make sure it aims at the air-outlet
grille
Replace the batteries
Temperature not within 7-35 C operating
range. If temperature within operating
short
on
range refer to Service Centre (check
room temperature sensor or relevant
circuit)
Drain out water from drain port at bottom
rear of the unit.
Page 13 of 15