Advertisement

Quick Links

Event Spot DTW
User Manual
Order codes:
LEDJ238 - (Black Housing)
LEDJ238A - (White Housing)

Advertisement

Table of Contents
loading

Summary of Contents for Ledj Event Spot DTW

  • Page 1 Event Spot DTW User Manual Order codes: LEDJ238 - (Black Housing) LEDJ238A - (White Housing)
  • Page 2: Safety Advice

    NO USER SERVICEABLE PARTS. pulling the power-cable. • This lighting fixture is for professional use only - it is • Make sure that the available mains supply voltage is not designed for or suitable for household use. The between 100~240V AC, 50/60Hz. product must be installed by a qualified technician in accordance with local territory regulations. The safety of • Make sure that the power cable is never crimped or the installation is the responsibility of the installer. The damaged. Check the equipment and the power cable fixture presents risks of severe injury or death due to fire periodically. hazards, electric shock and falls. • If the equipment is dropped or damaged, disconnect the • Warning! Risk Group 2 LED product according to mains power supply immediately and have a qualified EN 62471. Do not view the light output with optical engineer inspect the equipment before operating again. instruments or any device that may concentrate the beam. • WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Event Spot DTW User Manual...
  • Page 3 • PowerCON input/output • 3-Pin XLR input/output trailing sockets • Convection cooled • Optional IR remote (LEDJ90E) Specifications Event Spot DTW Power consumption 20° - Lux 6000 1496 Power supply 100~240V, 50/60Hz 45° - Lux 1940 77.8 Fuse T1A 250V Dimensions 203 x 135 x 173mm 20° 45° Weight 1.2kg Order code LEDJ238 - (Black Housing) LEDJ238A - (White Housing) 135mm 173mm www.prolight.co.uk Event Spot DTW User Manual...
  • Page 4: Technical Specifications

    MENU ENTER DOWN In the box: 1 x fixture, 01 - Earth point 1 x 10° frost lens, 02 - LCD display 06 - PowerCON input 1 x 45° frost lens, 03 - Function buttons 07 - PowerCON output 1 x power cable 04 - 3-Pin DMX input trailing socket 08 - Hanging bracket & 1 x user manual 05 - 3-Pin DMX output trailing socket 09 - Hanging bracket adjustable knob www.prolight.co.uk Event Spot DTW User Manual...
  • Page 5: Fixture Temperature

    Dimmer response DIMMER DIMMER RESP_02 DMX FAIL BLACKOUT DMX FAIL DMX FAIL DMX Fail Setting HOLD DMX FAIL STATIC Manual Dim:00 F:00 Manual Manual mode Dim: F: Manual Dim:99 F:99 Temperature Fixture temperature –– C www.prolight.co.uk Event Spot DTW User Manual...
  • Page 6: Master/Slave Mode

    2 channel mode: Channel Value Function 000-255 Master dimmer (0-100%) 000-002 No function 003-255 Strobe (slow-fast) Master/slave mode: To set the master unit, press the “MENU” button on the rear of the master unit to select manual mode. To set the other units in slave mode, press the “MENU” button on the rear of the unit to show “SLAVE MODE” on the LCD display. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. IR remote on/off: To set the IR remote on/off, press the “MENU” button on the rear of the unit to show “IR. REMOTE” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select “ON” or “OFF”. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. Dimmer response: To set the dimmer response, press the “MENU” button on the rear of the unit to show “DIMMER” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select “RESP_01” or “RESP_02”. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. www.prolight.co.uk Event Spot DTW User Manual...
  • Page 7 “HOLD” or “STATIC”. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. Manual dimming mode: To access the manual dimming mode, press the “MENU” button on the rear of the unit to show “Manual” on the LCD display. The unit is now in manual dimming mode. Press the “ENTER” button and use the “UP” and “DOWN” buttons to set the brightness from “00” - “99”. Press the “ENTER” button again and use the “UP” and “DOWN” buttons to set the strobe speed from “00” - “99”. Press the “ENTER” button to confirm the setting. (00 = LED off/strobe off, 99 = LED at full brightness/strobe fast) To exit out of any of the above options, press the “MENU” button. Fixture temperature: To check the fixtures temperature, press the “MENU” button on the rear of the unit to show “Temperature” on the LCD display. The fixture will now display the temperature. To exit out of any of the above options, press the “MENU” button. www.prolight.co.uk Event Spot DTW User Manual...
  • Page 8: Important Notes

    4 5 6 0 7 8 9 Optional IR remote Order code: LEDJ90E DMX address examples: To set the DMX address; • Press the “S” button, the LED illuminates in full, you can now start to set the DMX address • Select the required 3 digit DMX address (eg 001 or 136 or 275) the unit will then flash to confirm the address has been set • Now press the “DMX MODE” button to save the new address into the memory Important notes: • Set the DMX address on each fixture before plugging into the DMX controller • The IR remote is cannot be used when the fixture(s) are being controlled by a DMX controller • The maximum transmitter distance is 10m - Please make sure that you have the IR remote aimed directly at the front panel of each fixture to be programmed • If you do not press the “DMX MODE” button after you have changed the DMX address, when you power down the fixture it will lose the address you have set www.prolight.co.uk Event Spot DTW User Manual...
  • Page 9: Dmx Setup

    DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m Note: DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Event Spot DTW User Manual...
  • Page 10: Line Termination

    5-pin XLR (male) 3-pin XLR (female) Pin 1: GND (screen) Pin 1: GND (screen) Pin 2: Signal (-) Pin 2: Signal (-) Pin 3: Signal (+) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Event Spot DTW User Manual...
  • Page 11: Weee Notice

    WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Event Spot DTW User Manual...