Installation Instructions For Wsc Sleeve; Mounting Hardware; Wall Preparation - Friedrich WallMaster WE10B33C Installation And Operation Manual

115-volt/230-volt thru-the-wall air conditioners and heat pumps
Hide thumbs Also See for WallMaster WE10B33C:
Table of Contents

Advertisement

Available languages

Available languages

Installation instructions for WSC sleeve

Mounting hardware provided
ITEM NO.
DESCRIPTION
1
SCREW, #12A x 2"

Wall preparation

STEP 1
The wall opening required for a WSC SLEEVE is 17 ¼"
high by 27 ¼" wide.
STEP 2
LINTELS must be used in opening of brick veneer and
masonry walls to support the material above the WSC
SLEEVE. The following considerations should also be given:
Minimum Of 24" Required
From Top Of Unit To Ceiling.
Minimum Of 1" Spacing
Required On All Sides
1" Minimum
3 ½" For Subbase
10
QTY.
5
Inside Wall
Of The Unit.
920-007-13
A. Adjustable SUBBASE (SB) or other unit support must be provided
for panel wall type construction and for walls less than 8" thick.
B. A minimum distance of 1" must be allowed on all sides of the unit
to adjacent wall and floor. Where the subbase is required, the
minimum distance from the floor to the sleeve must be 3 ½". To
minimize chances of short cycling of the compressor, the minimum
clearance between the ceiling and the top of the unit should be
24". (See Figure 8).
Lintels
WSC Sleeve
Drain
Extension
" Minimum
9
1 6
Beyond Outside
Wall
Outside Wall
Figure 7

Advertisement

Table of Contents
loading

Table of Contents