Friedrich WallMaster WS08 Installation And Operation Manual

Friedrich WallMaster WS08 Installation And Operation Manual

Thru-the-wall air conditioners and heat pumps

Advertisement

Thru-the-wall
Air Conditioners and Heat Pumps
115-Volt: WS08, WS10, WS14
230-Volt: WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13
920-007-13 (8-07)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WallMaster WS08 and is the answer not in the manual?

Questions and answers

Summary of Contents for Friedrich WallMaster WS08

  • Page 1 Thru-the-wall Air Conditioners and Heat Pumps 115-Volt: WS08, WS10, WS14 230-Volt: WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13 920-007-13 (8-07)
  • Page 2: Table Of Contents

    Table of Contents Introduction Economizing Tips ............................................3 WS models How to operate your Friedrich room air conditioner ..................................4 To start unit ............................................... 4 To set mode of operation ..........................................4 To adjust temperature ............................................5 To adjust fan speed............................................5 To activate smart fan ............................................
  • Page 3: Electrical Data

    2. Do not block the fl ow of air to and from the unit - make sure the 11. Keep your Friedrich unit clean. Use a vacuum cleaner louvers are directed to give even dis tri bu tion of air throughout attachment for accessible parts, but take care not to damage the room.
  • Page 4: How To Operate Your Friedrich Room Air Conditioner

    920-007-13 How to operate your Friedrich room air con di tion er To start unit To activate Smart Fan (WY/WE heat-cool models) If your air conditioner is installed and plugged into a proper re cep ta cle, Press the Smart Fan button to activate the Smart Fan. The light it is ready to go.
  • Page 5: To Adjust Temperature

    920-007-13 Power Power Cool Cool Smart Fan Only Mode Speed Money Saver ® Speed Mode Heat Fan Only Clock Clock Money Timer Start Time Timer Start Time Saver On/Off Hour On/Off Hour Stop Time Stop Time Temp/Hour Temp/Hour 10 11 12 10 11 12 Figure 1: WS Model cool-only control panel Figure 2: WY/WE Model heat-cool control panel...
  • Page 6: To Set The Timer

    Timer On/Off function will not work. Figure 3: WY/WE heat-cool model remote control Additional RC1 wireless remote controls can be purchased from your Friedrich dealer. How to clean the air filter Your Friedrich room air conditioner is equipped with a Permafoam reusable air fi...
  • Page 7: How To Change Airfl Ow Direction

    CIRCUIT PROTECTION - Before installing or relocating your Reattach the DIS CHARGE GRILLE RE TAIN ER with the retaining Friedrich Room Air Conditioner, check the amp rating of the circuit screw. The unit is now ready to operate. breaker or "TIME-DELAY" fuse. Refer to the nameplate located on...
  • Page 8: Never Use An Extension Cord

    PLUG. NOTE: Your LCDI device will resemble one of these illustrations. Power cord information All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power RESET cord. The LCDI device meets the UL and NEC requirements for cord...
  • Page 9: Troubleshooting Tips And Home Maintenance

    If the unit operates, but won’t heat, determine if the control settings are correct. Adjust the ther mo stat to a warmer position to determine if it The decorative front of your Friedrich room air conditioner, as well operates. Also, check the fi lter and clean it thor ough ly, if needed.
  • Page 10: Installation Instructions For Wsc Sleeve

    920-007-13 Installation instructions for WSC sleeve Mounting hardware provided ITEM NO. DESCRIPTION QTY. SCREW, #12A x 2" Wall preparation A. Adjustable SUBBASE (SB) or other unit support must be provided STEP 1 The wall opening required for a WSC SLEEVE is 17 ¼" for panel wall type construction and for walls less than 8"...
  • Page 11: Installation Requirements

    920-007-13 Installation requirements STEP 1 The WSC SLEEVE should be positioned so that the STEP 4 The WSC SLEEVE must also be installed with a downward DRAIN EXTENSION extends a minimum of " beyond tilt toward the outside of the building. If a level is placed ⁄...
  • Page 12: Wallmaster Chassis Installation Instructions: Ws, We And Wy Models

    STEP 4 With the help of an assistant, remove the chassis from grille. Place lower edge into sleeve tab (Friedrich logo facing the shipping carton. Be careful not to allow anything to out). Align slots with screw holes. Secure grille with screws.
  • Page 13: Installation

    SLEEVE. Remove the rear WEATHER PANEL. Place lower STEP 4 With the help of an assistant, remove the chassis from edge into sleeve tab (Friedrich logo facing out). Align slots the shipping carton. Be careful not to allow anything to with screw holes. Secure grille with screws.
  • Page 14 920-007-13 STEP 5 CHASSIS SEAL GASKET INSTALLATION: After STEP 6 Remove the intake grille from the decorative front frame by installing the shell, slide the chassis into the shell stopping grasping it at the upper right and left side corners. Pull out approximately 3"...
  • Page 15: Condensate Removal

    New construction allowing for condensate drain systems built within In the event that the outdoor temperature drops below 37°F, any water the walls can use the Friedrich Interior Drain Kit (Accessory #IDK) that re mains in the chas sis basepan is drained into the sleeve pan on designed for installation in the bottom of the sleeve below the WE and WY models to prevent freezing.
  • Page 16 FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service.
  • Page 17: Warranty

    WARRANTY REGISTRATION: Please complete and return your Warranty Reg is tra tion Card (not this form) immediately and mail to FRIEDRICH. While it is not required that you do so in order to obtain warranty per for mance, it registers your warranty, making it easier and faster to verify the period of your warranty cover- age and to contact you, should fi...
  • Page 18 920-007-13...
  • Page 19 920-007-13...
  • Page 20 FRIEDRICH AIR CONDITIONING CO. Post Offi ce Box 1540 • San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212 210) 357-4400 • FAX (210) 357-4480 www.friedrich.com Printed in the U.S.A. 920-007-13 (8-07)

Table of Contents