2. If the specified sensor is Planar 12V, check XClarity Controller (XCC) and CMM event log for power-
supply-related issues and resolve those issues. If the problem remains, replace the system board
(trained technician only).
3. Contact local service provider. To locate a reseller authorized by Lenovo to provide warranty service,
go to http://www.ibm.com/partnerworld and click Business Partner Locator.
• FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810
User Action:
Complete the following steps until the problem is solved:
1. Check if any power adapter is missing, failing or not installed properly. If so, re-install or replace it.
2. Check the power adapter max rate and power capping policy. If the required power resource is not
met, change the power adapter or modify power capping mechanism.
.