Lenovo ThinkSystem SN550 V2 Reference page 138

Messages and codes reference
Table of Contents

Advertisement

4. Contact Lenovo Support.
• FQXSPUP4005I: FPGA firmware mismatch between nodes/servers [arg1] and [arg2]. Please
attempt to flash the FPGA firmware to the same level on all nodes/servers.
A mismatch of FPGA firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0133
User Action:
Complete the following steps until the problem is solved:
1. Reflash XCC/BMC firmware to the latest version on all servers.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPWD0000I: Watchdog Timer expired for [WatchdogElementName].
This message is for the use case when an implementation has detected a Watchdog Timer Expired.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0368
User Action:
Information only; no action is required
• FQXSPWD0001I: Reboot of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName].
This message is for the use case when an implementation has detected a Reboot by a Watchdog
occurred.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0370
User Action:
Information only; no action is required
• FQXSPWD0002I: Powering off system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName].
134
ThinkSystem SN550 V2 Messages and Codes Reference

Advertisement

Table of Contents
loading