Lenovo ThinkSystem SN550 V2 Reference page 52

Messages and codes reference
Table of Contents

Advertisement

• FQXSPIO0008N: A PCI SERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI SERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0234
User Action:
Complete the following steps:
1. Reseat the adapter or install the adapter to another slot.
2. If the problem still exist then replace the adapter.
3. If the problem still exist then contact local service.
• FQXSPIO0010I: A Correctable Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Correctable Error.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0238
User Action:
Information only; please correct the error recorded in system log to resolve the error
• FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0240
User Action:
Check http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error.
1. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and
firmware.
2. Check the event log of XClarity Controller for additional information about failing components.
3. If there are no entries related to the error in the event log, contact Lenovo support.
• FQXSPIO0013N: A Fatal Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Fatal Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
48
ThinkSystem SN550 V2 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7x16

Table of Contents