• FQXSPPW0061M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps to solve:
1. Ensure power supply unit meets the wattage and efficiency level in the system spec and matches
with supported list.
2. Check the event log in XClarity Controller (XCC)/CMM2 Web GUI to the detail information to reseat/
reinstall/upgrade the power supply unit.
3. If the problem still exists, please contact Lenovo Support
• FQXSPPW0062M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
Please replace the installed power supply unit which is supported in server proven plan. (https://static.
lenovo.com/us/en/serverproven/flex/8721_7893.shtml)
• FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. If the specified sensor is Planar 3.3V or Planar 5V, replace the system board (trained technician only).
94
ThinkSystem SN550 V2 Messages and Codes Reference