I. CAUTIONS BEFORE OPERATION
Following items have to be checked every working day before the operation of the machine
and before the start of work hours.
1.
Ascertain that the sewing machine is filled with the predetermined amount of oil.
2.
Never operate the machine unless the lubricating part in the hook has been filled up with oil.
3.
Ascertain that the pressure gauge indicates the designated air pressure of 0.5 MPa.
* (This is necessary particularly when the compressor is stopped for a lunch break or the like.)
If the compressed air pressure is equal to or less than the designated value, troubles such as
interference between the parts can occur. It is therefore necessary to carefully check the com-
pressed air pressure.
4.
Check whether the needle thread/bobbin thread need to be replenished.
5.
To perform sewing immediately after turning ON the power switch, perform trial stitching first,
then proceed with sewing of actual products after the test sewing.