JUKI APW-895NE Instruction Manual page 81

Table of Contents

Advertisement

No.
Corner knife motor origin compensation
Origin of corner knife motor is compensated.
Marking light origin compensation (just under)
Origin of marking light motor is compensated. Origin is in the state that
it irradiates light just under and located at the position of 230 mm from
needle.
* In case of
the position of 246 mm from the needle.
Marking light origin compensation (needle side)
Position of needle side from origin of marking light motor is compensat-
ed. Light irradiation position is 80 mm from needle.
* In case of
the position of 96 mm from the needle.
Marking light origin compensation (operator side)
Position of operator side from origin of marking light motor is compen-
sated. Light irradiation position is 380 mm from needle.
* In case of
the position of 396 mm from the needle.
Back tack motor origin compensation
Origin of back tack motor is compensated.
Item
Long and wide type, light irradiation position is at
Long and wide type, light irradiation position is at
Long and wide type, light irradiation position is at
− 65 −
Setting range
/
Initial value
Edit unit
−5.0 to 5.0
0.0mm
/
0.1mm
−500 to
0 pulse
500
/
1 pulse
−500 to
0 pulse
500
/
1 pulse
−500 to
0 pulse
500
/
1 pulse
−30 to 30
0 pulse
/
1 pulse