3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates an inlet power
socket and consists of one green terminal block connector within 6 contacts. Please
follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
IGS-6325-16P4S: DC 48-56V
IGS-6325-16T4S: DC 9-48V, AC 24V
6
DI 0 DI 1 DO 0 DO 1 GND GND
1 2 3 4 5 6
1 2 3 4 5 6
V1+
1A@24V
DC1
Input: 48-56V
Dual power input is required
for maximum PoE loading.
Refer to user's manual for
more details.
Figure 3-1: IGS-6325-16P4S Upper Panel
DI0
DI1 DO0 DO1
1 2 3 4 5 6
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+
PWR1
Fault
DC Input: 9-48V
AC Input: 24V , 1.2A max.
Figure 3-2: IGS-6325-16T4S Upper Panel
V2+
DC2
, 7.5A max.
GND
GND
V2+
PWR2
, 3.3A max.