Table of Contents 1. Package Contents ................. 3 2. Requirements ..................5 3. Wiring the Power Inputs ............... 6 3.1 Grounding the Device ..............9 4. Terminal Setup ................... 10 4.1 Logging on to the Console ............11 4.2 Configuring IP Address via Console ..........12 5.
Page 4
Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items: DB9 to RJ45 Quick Wall RJ45 SFP Industrial Interface Installation Mounting Dust Dust Managed RS232 Guide sheet Switch Console Cable IGS-6325- 16P4S IGS-6325- ...
2. Requirements Industrial Managed Switch provides remote login interface management purposes. The following equipment is necessary for further management: z Workstations running Windows XP/2003/7/10/11, MAC OS 10.15 or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols. z Workstations are installed with Ethernet NIC (Network Interface Card). z Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector within 6 contacts. Please follow the steps below to insert the power wire. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
Page 8
1. The wire gauge for the terminal block should be in the range from 12 to 24 AWG. 2. Please check the wire AWG Ampere specification before connecting PLANET Industrial Managed Switch. PWR1 and PWR2 must provide the same DC voltage for power load balance while operating with dual power input.
3.1 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. Earth Ground DI 0 DI 1 DO 0 DO 1 GND GND 1 2 3 4 5 6 1 2 3 4 5 6 1A@24V Input: 48-56V...
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. IGS Industrial Managed Switch PC/Workstation with Terminal Emulation Software Console 115200,N,8,1 RJ45 to DB9 RS232 Cable...
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. The following console screen is based on the IGS-6325-16P4S. The display of the IGS-6325 series is the same as that of the IGS-6325-16P4S.
4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows: Display of the current IP Address 1. At the “#” prompt, enter “show ip interface brief”. IGS-6325-Series # show ip interface brief 2. The screen displays the current IP address shown in Figure 4-2.
Page 13
The previous command would apply the following settings for the Industrial Managed Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 4-3: Configuring IP Address Screen 4. Repeat step 1 to check if the IP address has changed. Storing current switch configuration 5. At the “#” prompt, enter the following command and press <Enter>. # copy running-config startup-config Figure 4-4: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed Switch will apply...
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
5.1 Logging in to the Industrial Managed Switch 1. Use Chrome 98.0.xxx or above for Web browser and enter IP address https://192.168.0.100 (the factory-default IP address) to access the Web interface. 2. When the following dialog box appears, please enter the default user name “admin”...
Page 16
The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more. If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description.