Controller Functionality
6.2.3

Secure Mode

The Mode LED is red.
Only Secure and Master Users can access the premises during the
Secured Mode.
A Secure User must enter their Primary and Secondary codes to gain
entry. After entering their Primary code, the Door LED flashes green
for 10 seconds, during which the Secondary code must be entered. A
Master User only needs to present the code once to gain entry.
6.3

Changing the Modes of Operation

6.3.1

Changing from Normal Mode to Secure Mode

The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1. Enter the Normal/Secure code.
The Mode LED flashes red.
2. Press the "#" key to confirm the mode change.
The Mode LED turns red.
6.3.2

Changing from Secure Mode to Normal Mode

The default factory setting for the Normal/Secure code is 3838.
To change from Secure to Normal mode:
1. Enter the Normal/Secure code.
The Mode LED flashes green.
AYC-E/Q60 Family Instruction Manual
Mode/Transmit
Red
Door/Program
Mode/Transmit
Green
Mode/Transmit
Red
Mode/Transmit
Red
Mode/Transmit
Red
Mode/Transmit
Green
Door/Program
Door/Program
Door/Program
Door/Program
Door/Program
39

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AYC-E/Q60 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents