Perkins 2506J-E15TA Operation And Maintenance Manual page 69

Industrial
Table of Contents

Advertisement

M0076814-03
Table 9
Equation For Adding The SCA To The Heavy-Duty Coolant At
The Initial Fill
V × 0.07 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 10 is an example for using the equation that is
in Table 9 .
Table 10
Example Of The Equation For Adding The SCA To The Heavy-
Duty Coolant At The Initial Fill
Total Volume of the
Multiplication
Cooling System (V)
Factor
15 L (4 US gal)
× 0.07
Adding The SCA to The Heavy-Duty
Coolant For Maintenance
Heavy-duty antifreeze of all types REQUIRE periodic
additions of an SCA.
Test the antifreeze periodically for the concentration
of SCA. For the interval, refer to the Operation and
Maintenance Manual, "Maintenance Interval
Schedule" (Maintenance Section). Cooling System
Supplemental Coolant Additive (SCA) Test/Add.
Additions of SCA are based on the results of the test.
The size of the cooling system determines the
amount of SCA that is needed.
Use the equation that is in Table 11 to determine the
amount of SCA that is required, if necessary:
Table 11
Equation For Adding The SCA To The Heavy-Duty Coolant
For Maintenance
V × 0.023 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 12 is an example for using the equation that is
in Table 11 .
Table 12
Example Of The Equation For Adding The SCA To The Heavy-
Duty Coolant For Maintenance
Total Volume of the
Multiplication
Cooling System (V)
Factor
15 L (4 US gal)
× 0.023
Cleaning the System of Heavy-Duty
Antifreeze
Note: Before corrosion inhibitors can be effective the
cooling system must be free from rust, scale and
deposits.
• Drain the cooling system.
• Before filling the cooling system with acceptable
Amount of SCA
that is Required
(X)
Most commercial cooling system cleaning agents are
1.05 L (35.5 oz)
corrosive and their use is not recommended by
Perkins.
The cooling system must be thoroughly flushed with
clean water after using cleaning agents.
Cleaning agents for marine or industrial cooling sys-
tem must not be used, these areveryaggressiveand
can cause damage to cooling system components.
• Run the engine for approximately 30 minutes and
• Take a sample of the solution from the cooling
• Allow the sample to sit for at least 30 minutes and
• Flush the system with clean water.
• Fill the system with new coolant.
Fluid Recommendations
General Lubricant Information
Because of government regulations regarding the
certification of exhaust emissions from the engine,
the lubricant recommendations must be followed.
Amount of SCA
• API
that is Required
(X)
• SAE
0.35 L (11.7 oz)
• ACEA
• ECF-3
quality water, pre-dissolve the cleaning agent in
the water. Use a non-foaming detergent to clean
oil contamination, consult your Perkins dealer for
suitable product.
NOTICE
then leave the engine to cool down.
system, drain the system.
check for signs of oil and deposits. If oil and
deposits are still present repeat the procedure.
American Petroleum Institute
Society Of Automotive Engineers Inc.
Association des Constructers
European Automobiles.
69
Maintenance Section
Fluid Recommendations
i08273319
Engine Crankcase Fluid