28
Operation Section
Product Storage
Remove any ATAAC lines, air cleaners, or other
attachments that would otherwise interfere with the
lift chains or other lifting devises. The engine
package center of gravity will change depending on
the engine attachments. Adjust the spreader bar and
chains as necessary to maintain a lift within 5
degrees of horizontal in all directions.
Radiator Only
Detach the radiator, and mounting bracket at the
engine front support. Add eyebolts or lifting brackets
to the threaded holes marked for lifting.
Clean Emission Module (CEM)
Lifting
Illustration 27
Typical example
(1) CEM lifting eyes
(2) CEM lifting eyes
Ensure that all 4 lifting eyes are used when lifting the
CEM. Only use the lifting eyes (1) and lifting eyes (2)
for lifting the CEM, refer to illustration 27 .
Pump Electronic Tank Unit (PETU)
Illustration 28
Typical example
(1 PETU lifting eyes
Product Storage
(Engine and Aftertreatment)
Your Perkins distributor can help in preparing the
engine for extended storage periods.
Some applications, the engine can be equipped with
delayed engine shutdown. Allow at least 2 minutes
after the engine has stopped before you turn the
battery disconnect switch to OFF. Disconnecting the
battery power too soon will prevent purging of the
g06042325
DEF fluid lines after the engine is shut down. Also,
during the 2 minutes the engine electronic control
module is active storing information from the engine
and aftertreatment sensors.
Condition for Storage
An engine can be stored for up to 6 months provided
all the recommendation are adhered to.
M0076814-03
g06129926
i06605082

Advertisement

Table of Contents
loading

This manual is also suitable for:

2506f-e15ta

Table of Contents