1. Enter the Alarm Output Settings interface: Configuration> Event > Basic Event >
Alarm Output.
2. Select one alarm output channel in the Alarm Output drop-down list. You can
also set a name for the alarm output (optional).
3. The Delay time can be set to 5sec, 10sec, 30sec, 1min, 2min, 5min, 10min or
Manual. The delay time refers to the time duration that the alarm output
remains in effect after alarm occurs.
4. Click Arming Schedule to enter the Edit Schedule Time interface. The time
schedule configuration is the same as the settings of the arming schedule for
motion detection Refer to Task 1: Set the Arming Schedule in Section 9.1.1.
5. You can copy the settings to other alarm outputs.
6. Click Save to save the settings.

9.1.3 Handling Exception

The exception type can be HDD full, HDD error, network disconnected, IP address
conflicted and illegal login to the cameras.
Steps: