Specifi cation
Number
INSTRUCTIONS
5221
MODEL: Outdoor Camera Housings
CWKFD2/CWKFD12 Cold Weather Kit
This unit is designed for operation in an
NOTE:
upright position. Installing the Fusionome™
upside down may cause damage to the
internal equipment, and will void the war-
ranty.
STANDARD INSTALLATION PROCEDURE
INCLUDES MODELS:
CWKFD2 /CWKFD12
1. You must fi rst remove the main housing bracket to install the
optional heater and blower kit. Remove (3) 10 x 32 Bolts
(Figure 1).
10 x 32 bolts
Figure 1
2. The blower installs on the front side of the main housing
bracket. Secure in place using (2) 4 x 40 x 5/8" bolts and (2)
star washers (Figure 2).
3. The heater is installed on the backside of the main housing
bracket. First, clean the mounting surface area with rubbing
alcohol. Remove the protective fi lm from the back of heater
and press it on to the bracket (Figure 2).
Bolts
Figure 2
2525 Park Central Blvd. • Decatur, Ga 30035 • (770) 987-7550 • 800-554-1124 U.S. & Canada • www.videolarm.com • Fax 800-826-0366
Catalog
Section
2
Star washers
Blower
Blower
25 Watt Heater
REVISION DATE: 02-02-2009
PRODUCT INSTRUCTIONS
4. The blower wire connector is attached to the connector marked
"BLR2" on the PC Board. The Red wire should be facing the
"+" symbol on the board. Wires on the connector should
be facing down towards the bracket. The spiral wrapped wires
from the blower MUST fi t into the notch on the side of the
bracket (Figure 3).
Heater connector
Spiral wire from blower
must fi t into notch on side
of bracket
Figure 3
5. Heater wires are attached to the (4) position heater-terminal
block. These (2) wires should be installed in the last (2)
positions of the terminal block near the corner of the PC
Board.
6. When installing main housing bracket back into the housing
check to see that the wires for the main connector are facing
the bracket as shown in fi gure 4
Wires face towards bracket
Figure 4
7. A new rating label is included with this cold weather kit. Peel
the label off of the backing and place over the old rating label
inside the housing.