MadgeTech Bridge101A Product Information Card

Advertisement

Quick Links

Description
Range
Resolution
Accuracy
1,000,000 readings; software configurable memory wrap
Memory
330,000 readings in multiple start/stop
Wrap Around
Reading Rate
LED Indicator
Units
V, mV, µV, Engineering Units specified through software
Required Interface
Baud rate
10 months typical at a 1 minute reading rate with a 350 Ω load
*Battery Life
2 years typical at a 1 minute reading rate with a 1000 Ω load
Operating Environment
-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 90 %RH non-condensing
Material
Dimensions
1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Weight
Approvals
*MadgeTech recommends using 350 or 1000 Ω strain gages. 120 Ω strain gauges can be used with the Bridge101A but
it is not recommended as it will reduce the battery life, potentially increase noise level and limit the low end temperature
operation.
*Bridge101A Range, Resolution and Accuracy
Nominal Range
±30 mV
Measurement Range
±30 mV
Resolution
1 µV
±0.01% FSR;
Calibrated Accuracy
±3 Microvolts
Input Range
0 to 2.5V
Reference Voltage
2.5 V
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE.
BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
1.888.610.7664
Bridge101A
See Table Below*
Yes
4Hz to 1 every 24 hours
Red and Green
IFC200
115,200
ABS plastic
0.8 oz (24 g)
CE
±150 mV
±1000 mV
±160 mV
±1200 mV
5 µV
50 µV
±0.01% FSR;
±0.01% FSR;
±16 Microvolts
±120 Microvolts
0 to 2.5 V
0 to 2.5 V
2.5 V
2.5 V
DOC 1242035-00 REV 16 2015.04.14
www.calcert.com
10
15
20
5
25
0
30
Product Information Card
Bridge101A-30
30mV Bridge Data Logger
Bridge101A-150
150mV Bridge Data Logger
Bridge101A-1000
1000mV Bridge Data Logger
sales@calcert.com
Bridge101A

Advertisement

loading

Summary of Contents for MadgeTech Bridge101A

  • Page 1 Approvals *MadgeTech recommends using 350 or 1000 Ω strain gages. 120 Ω strain gauges can be used with the Bridge101A but it is not recommended as it will reduce the battery life, potentially increase noise level and limit the low end temperature operation.
  • Page 2 - Downloading will offload and save all the recorded data to the PC. *MadgeTech recommends using 350 or 1000 Ω strain gages. 120 Ω strain gauges can be used with the Bridge101A but it is not recommended as it will reduce the battery life, potentially increase noise level and Device Maintenance limit the low end temperature operation.